Skip to content
SafetyRecord logoSafetyRecord
DOUGLAS DEVELOPMENT CORP
$44,109
penalties
46
viol.
10
insp.

DOUGLAS DEVELOPMENT CORP

77 P STREET, NE, WASHINGTON, DC 20002NAICS 236220 Commercial and Institutional Building Construction

Inspections
10
Dec 1997 to Nov 2021 · 10 safety, 0 health
Violations
46
across 10 inspections
Penalties on record
$44,109
latest amounts in DOL records
By classification
Serious 44Willful 0Repeat 1Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 15, 2021Planned (H) · No Inspection scope, Safety#345643316$00 viol.

Inspection #345643316

Dates

Opened
Nov 15, 2021
Closing Conference Date
Nov 15, 2021
Closed
Jan 14, 2022

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
655 New York Ave Nw, Washington, DC 20001
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 25, 2019Planned (H) · No Inspection scope, Safety#344498142$00 viol.

Inspection #344498142

Dates

Opened
Nov 25, 2019
Closing Conference Date
Nov 25, 2019
Closed
Mar 9, 2020

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
0 reported

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1900 Half Street, Washington, DC 20024
Industry
531190 Lessors of Other Real Estate Property

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 19, 2012Programmed Related (I) · Partial scope, Safety#334440344$12,7442 viol.

Inspection #334440344

Dates

Opened
Apr 19, 2012
Closing Conference Date
Apr 19, 2012
Final Order
Nov 8, 2012
Closed
May 16, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 repeat
Initial Penalties
$12,744
Penalties on Record
$12,744
Site Address
805 Channing Place Ne, Washington, DC 20001
Industry
236220 Commercial and Institutional Building Construction

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.34
Means of Egress
OSHA citation code: 19260034 C
Serious17$1,964$1,964-Nov 8, 2012
020011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Repeat13$10,780$10,780-Nov 8, 2012
Mar 29, 2011Programmed Related (I) · Complete scope, Safety#315333948$6,6158 viol.

Inspection #315333948

Dates

Opened
Mar 29, 2011
Closing Conference Date
Mar 29, 2011
Closed
Sep 8, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
8
Violation Types
7 serious, 1 other-than-serious
Initial Penalties
$13,230
Penalties on Record
$6,615
Site Address
641 S Street, Nw, Washington, DC 20001
Industry
236220 Commercial and Institutional Building Construction

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (5 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious11$2,520$1,260May 6, 2011--
010021926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 IV
Serious11$1,890$945May 7, 2011--
010031926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 I02 I
Serious15$2,520$1,260May 6, 2011--
010041926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious15$4,410$2,205May 6, 2011--
01005B1926.850
Preparatory Operations (Demolition)
OSHA citation code: 19260850 F
Other15$0$0May 11, 2011--

Showing the 5 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Sep 10, 2001Referral (C) · Complete scope, Safety#303856967$7,5004 viol.

Inspection #303856967

Dates

Opened
Sep 10, 2001
Closing Conference Date
Sep 10, 2001
Closed
Aug 4, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$7,500
Penalties on Record
$7,500
Site Address
1023 7th Street, Washington, DC 20001
Industry
236220 Commercial and Institutional Building Construction

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious15$3,000$3,000Sep 19, 2001--
01002A1926.850
Preparatory Operations (Demolition)
OSHA citation code: 19260850 A
Serious15$1,500$1,500Sep 24, 2001--
01002B1926.851
Stairs, Passageways, and Ladders (Demolition)
OSHA citation code: 19260851 B
Serious15$0$0Sep 19, 2001--
010031926.854
Removal of Walls, Masonry Sections, and Chimneys
OSHA citation code: 19260854 A
Serious15$3,000$3,000Sep 24, 2001--
Jul 16, 2001Referral (C) · Complete scope, Safety#303856397$3,8003 viol.

Inspection #303856397

Dates

Opened
Jul 16, 2001
Closing Conference Date
Jul 16, 2001
Closed
Oct 21, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$3,800
Penalties on Record
$3,800
Site Address
702 H Street, Nw, Washington, DC 20001
Industry
236220 Commercial and Institutional Building Construction

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious11$800$800Jul 25, 2001--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious13$1,000$1,000Jul 25, 2001--
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious13$2,000$2,000Jul 25, 2001--
Sep 14, 2000Referral (C) · Complete scope, Safety#301472932$00 viol.

Inspection #301472932

Dates

Opened
Sep 14, 2000
Closing Conference Date
Sep 14, 2000
Closed
Sep 27, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
825 7th Street, Nw, Washington, DC 20001
Industry
236220 Commercial and Institutional Building Construction

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Apr 12, 2000Planned (H) · Partial scope, Safety#301470811$00 viol.

Inspection #301470811

Dates

Opened
Apr 12, 2000
Closing Conference Date
Apr 12, 2000
Closed
Apr 19, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
77 P Street, Ne, Washington, DC 20002
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Oct 14, 1999Referral (C) · Complete scope, Safety#301468328$7,6006 viol.

Inspection #301468328

Dates

Opened
Oct 14, 1999
Closing Conference Date
Oct 14, 1999
Closed
Dec 8, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4
Related Activity
1 referral

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$8,400
Penalties on Record
$7,600
Site Address
702 H Street, Nw, Washington, DC 20001
Industry
236220 Commercial and Institutional Building Construction

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (5 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.102
Eye and Face Protection (Construction)
OSHA citation code: 19260102 A01
Serious11$1,200$1,000Oct 24, 1999--
01002A1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious11$2,100$1,500Oct 24, 1999--
01002B1926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 A01
Serious11$0$0Oct 24, 1999--
01003A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F14
Serious11$900$900Oct 24, 1999--
01003B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F15
Serious11$0$0Oct 24, 1999--

Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Dec 4, 1997Unprogrammed Related (G) · Complete scope, Safety#301100632$5,85023 viol.

Inspection #301100632

Dates

Opened
Dec 4, 1997
Closing Conference Date
Dec 5, 1997
Closed
Feb 1, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9
Related Activity
1 referral

Violations and Penalties

Total Violations
23
Violation Types
23 serious
Initial Penalties
$5,850
Penalties on Record
$5,850
Site Address
704-718 7th Street, N.w., Washington, DC 20001
Industry
236220 Commercial and Institutional Building Construction

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (5 of 23 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B01
Serious13$450$450Jan 22, 1998--
01001B1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Serious19$0$0Dec 24, 1997--
01001C1926.21
Safety Training and Education
OSHA citation code: 19260021 B02
Serious19$0$0Dec 30, 1997--
01001D1926.95
Criteria for Personal Protective Equipment (Construction)
OSHA citation code: 19260095 A
Serious22$0$0Dec 24, 1997--
010021926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious11$600$600Dec 24, 1997--

Showing the 5 violations listed first by citation identifier. This inspection has 23 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 10 of 10, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements7 citations · $4,500
1926.501Fall Protection - Duty to Have Fall Protection6 citations · $21,235
1926.1052Stairways (Construction)3 citations · $945

Industry comparison

Violations per inspection
This employer4.6
Industry average1.5
Penalties per inspection
This employer$4,411
Industry average$1,290

Construction of Buildings, 208,845 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in WASHINGTON, DC

All employers in WASHINGTON →