Skip to content
SafetyRecord logoSafetyRecord
ESCOSIA STEEL SERVICES, INC.
$2,325
penalties
10
viol.
1
insp.

ESCOSIA STEEL SERVICES, INC.

2819 LARIMER STREET, DENVER, CO 80205

Inspections
1
Mar 1998 to Mar 1998 · 0 safety, 1 health
Violations
10
across 1 inspection
Penalties on record
$2,325
latest amounts in DOL records
By classification
Serious 10Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 9, 1998Complaint (B) · Complete scope, Health#302066287$2,32510 viol.

Inspection #302066287

Dates

Opened
Mar 9, 1998
Closing Conference Date
May 5, 1998
Closed
Sep 11, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
10 serious
Initial Penalties
$4,650
Penalties on Record
$2,325
Site Address
2819 Larimer Street, Denver, CO 80205
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling16 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Butanone10.7082ppm
Antimony and Compounds (as Sb)60mg/m³
Beryllium and Beryllium Compounds (as Be)60mg/m³
Chromium, Metal and Insoluble Salts60 - 0.0012mg/m³
Cobalt, Metal, Dust and Fume (as Co)60mg/m³
Copper Fume (as Cu)60.0037 - 0.0134mg/m³
Iron Oxide Fume60.6338 - 2.8397mg/m³
Lead, Inorganic (as Pb)60mg/m³
Manganese Fume (as Mn)60.0155 - 0.0639mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)60mg/m³
n-Butyl Acetate10.5489ppm
Nickel, Metal and Insoluble compounds (as Ni)60mg/m³
Toluene12.6833ppm
Vanadium fume (as V2O5)60mg/m³
Xylene121.138ppm
Zinc Oxide Fume60.0012 - 0.0025mg/m³

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 C
Serious11$600$300May 22, 1998--
01002A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Serious33$600$300Jun 9, 1998--
01002B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious33$0$0Jun 9, 1998--
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Serious29$600$300May 15, 1998--
010041910.132
General requirements
OSHA citation code: 19100132 D02
Serious19$600$300May 15, 1998--
010051910.133
Eye and Face Protection
OSHA citation code: 19100133 A05
Serious22$750$375May 15, 1998--
01006A1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Serious27$750$375May 15, 1998--
01006B1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Serious11$0$0May 15, 1998--
01006C1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 D
Serious11$0$0May 15, 1998--
010071910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G02 III
Serious27$750$375May 15, 1998--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Wiring methods, components, and equipment for general use4 citations · $750
1910.95Occupational Noise Exposure2 citations · $300
1910.221 citation · $300

Chemical exposure sampling

Samples
76
Substances
16
Inspections
1

Other inspected employers in DENVER, CO

All employers in DENVER →