FETERL MANUFACTURING COMPANY
$1,720
penalties
23
viol.
5
insp.

FETERL MANUFACTURING COMPANY

411 WEST CENTER, SALEM, SD 57058

Inspections
5
May 1985 to Dec 1991 · 4 safety, 1 health
Violations
23
across 5 inspections
Penalties on record
$1,720
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 12, 1991Planned (H) · Complete scope, Safety#100565225$1,4709 viol.

Inspection #100565225

Dates

Opened
Dec 12, 1991
Closing Conference Date
Dec 12, 1991
Closed
Apr 10, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
85

Violations and Penalties

Total Violations
9
Violation Types
9 serious
Initial Penalties
$2,450
Penalties on Record
$1,470
Site Address
Southwest Of Town, Salem, SD 57058
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious21$525$315Feb 18, 1992--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious23$0$0Feb 18, 1992--
01001C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious23$0$0Feb 18, 1992--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious34$875$525Feb 18, 1992--
01003A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious12$525$315Feb 18, 1992--
01003B1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious44$0$0Feb 18, 1992--
01003C1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious54$0$0Feb 18, 1992--
01003D1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious12$0$0Feb 18, 1992--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious145$525$315Feb 18, 1992--
Mar 22, 1988Planned (H) · Complete scope, Safety#101453504$00 viol.

Inspection #101453504

Dates

Opened
Mar 22, 1988
Closing Conference Date
Mar 22, 1988
Closed
Mar 28, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
100

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Southwest Of Town, Salem, SD 57058
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 21, 1985Follow-Up (F) · Partial scope, Safety#643270$00 viol.

Inspection #643270

Dates

Opened
Nov 21, 1985
Closing Conference Date
Nov 21, 1985
Closed
Nov 21, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
72

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
411 West Center, Salem, SD 57058
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 31, 1985Referral (C) · Partial scope, Safety#640870$2505 viol.

Inspection #640870

Dates

Opened
Jul 31, 1985
Closing Conference Date
Jul 31, 1985
Closed
Dec 3, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
72
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
3 serious, 2 other-than-serious
Initial Penalties
$250
Penalties on Record
$250
Site Address
411 West Center, Salem, SD 57058
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious810$250$250Nov 4, 1985--
01001B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious410$0$0Nov 4, 1985--
01001C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious14$0$0Oct 8, 1985--
020011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other12$0$0Oct 8, 1985--
020021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other12$0$0Oct 8, 1985--
May 13, 1985Planned (H) · Complete scope, Health#647107$09 viol.

Inspection #647107

Dates

Opened
May 13, 1985
Closing Conference Date
May 14, 1985
Closed
Aug 27, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
72

Violations and Penalties

Total Violations
9
Violation Types
9 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
411 W Center, Salem, SD 57058
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)40mg/m³
Cadmium Fume (as Cd)40mg/m³
Chromium, Metal and Insoluble Salts40 - 0.0215mg/m³
Cobalt, Metal, Dust and Fume (as Co)40.0016 - 0.0064mg/m³
Copper Fume (as Cu)40 - 0.0326mg/m³
Iron Oxide Fume40.6627 - 5.1849mg/m³
Lead, Inorganic (as Pb)40mg/m³
Manganese Fume (as Mn)40.0051 - 0.4025mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40mg/m³
Particulates not otherwise regulated (Respirable Fraction)50mg/m³
Vanadium fume (as V2O5)40mg/m³
Zinc Oxide Fume40.0044 - 0.1274mg/m³

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.20
Access to Employee Exposure and Medical Records
OSHA citation code: 19100020 G01 I
Other11$0$0Aug 12, 1985--
010021910.20
Access to Employee Exposure and Medical Records
OSHA citation code: 19100020 G01 II
Other11$0$0Aug 12, 1985--
010031910.20
Access to Employee Exposure and Medical Records
OSHA citation code: 19100020 G01 III
Other11$0$0Aug 12, 1985--
010041910.20
Access to Employee Exposure and Medical Records
OSHA citation code: 19100020 G02
Other11$0$0Aug 12, 1985--
010051910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D03
Other25$0$0Aug 12, 1985--
010061910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 I
Other14$0$0Jul 28, 1985--
010071910.95
Occupational Noise Exposure
OSHA citation code: 19100095 L01
Other25$0$0Aug 12, 1985--
010081910.134
Respiratory Protection
OSHA citation code: 19100134 B05
Other11$0$0Jul 28, 1985--
010091910.134
Respiratory Protection
OSHA citation code: 19100134 E05 I
Other11$0$0Aug 12, 1985--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus4 citations · $525
1910.20Access to Employee Exposure and Medical Records4 citations · $0
1910.95Occupational Noise Exposure3 citations · $0

Chemical exposure sampling

Samples
57
Substances
14
Inspections
1

Other inspected employers in SALEM, SD

All employers in SALEM →