Skip to content
SafetyRecord logoSafetyRecord
GENERAL MASONRY
$20,800
penalties
45
viol.
5
insp.

GENERAL MASONRY

728 SOUTH WARNOCK STREET, PHILADELPHIA, PA 19153NAICS 238140 Masonry Contractors

Inspections
5
Aug 1983 to Jul 2014 · 5 safety, 0 health
Violations
45
across 5 inspections
Penalties on record
$20,800
latest amounts in DOL records
By classification
Serious 27Willful 0Repeat 3Other 15

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 7, 2014Referral (C) · Partial scope, Safety#339857468$11,20010 viol.

Inspection #339857468

Dates

Opened
Jul 7, 2014
Closing Conference Date
Jul 7, 2014
Final Order
Nov 20, 2014
Closed
Aug 27, 2018

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2
Related Activity
1 referral

Violations and Penalties

Total Violations
10
Violation Types
10 serious
Initial Penalties
$11,200
Penalties on Record
$11,200
Site Address
728 South Warnock Street, Philadelphia, PA 19147
Industry
238140 Masonry Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 VII
Serious12$2,800$2,800Aug 13, 2014-Nov 20, 2014
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Serious12$0$0Aug 19, 2014-Nov 20, 2014
01002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious12$2,000$2,000Aug 13, 2014-Nov 20, 2014
01002B1926.454
Scaffolding - Training
OSHA citation code: 19260454 A
Serious12$0$0Aug 26, 2014-Nov 20, 2014
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F06
Serious12$2,000$2,000Aug 13, 2014-Nov 20, 2014
010041926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Serious12$2,000$2,000Aug 13, 2014-Nov 20, 2014
01005A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious12$1,200$1,200Aug 19, 2014-Nov 20, 2014
01005B1910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Serious12$0$0Aug 13, 2014-Nov 20, 2014
01005C1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Serious12$0$0Aug 26, 2014-Nov 20, 2014
010061926.95
Criteria for Personal Protective Equipment (Construction)
OSHA citation code: 19260095 A
Serious12$1,200$1,200Aug 13, 2014-Nov 20, 2014
Apr 23, 1986Referral (C) · Complete scope, Safety#100423177$5,40013 viol.

Inspection #100423177

Dates

Opened
Apr 23, 1986
Closing Conference Date
Apr 23, 1986
Contested
Oct 29, 1986
Final Order
Jun 1, 1987
Closed
Jan 31, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
19
Related Activity
1 referral

Violations and Penalties

Total Violations
13
Violation Types
7 serious, 2 repeat, 4 other-than-serious
Initial Penalties
$11,700
Penalties on Record
$5,400
Site Address
Drexel Univ. Dormitory - 34th & Arch Streets, Philadelphia, PA 19104
Industry
238140 Masonry Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (10 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B01
Serious119$600$300Oct 8, 1986Oct 29, 1986Jun 1, 1987
010021926.25
Housekeeping
OSHA citation code: 19260025 A
Serious119$500$200Sep 19, 1986Oct 29, 1986Jun 1, 1987
010031926.350
Gas Welding and Cutting
OSHA citation code: 19260350 J
Serious119$600$300Sep 18, 1986Oct 29, 1986Jun 1, 1987
010041926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 A
Serious1519$600$300Sep 19, 1986Oct 29, 1986Jun 1, 1987
010051926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 A
Serious3019$600$300Sep 19, 1986Oct 29, 1986Jun 1, 1987
010061926.402
Applicability (Electrical - Construction)
OSHA citation code: 19260402 A05
Serious119$600$300Sep 19, 1986Oct 29, 1986Jun 1, 1987
010071926.552
Material Hoists, Personnel Hoists, and Elevators
OSHA citation code: 19260552 B02 I
Serious1519$800$400Sep 19, 1986Oct 29, 1986Jun 1, 1987
020011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Repeat23$6,000$2,700Sep 19, 1986Oct 29, 1986Jun 1, 1987
020021926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 D01
Repeat1419$1,200$600Sep 19, 1986Oct 29, 1986Jun 1, 1987
030011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other119$100$0Sep 19, 1986Oct 29, 1986Jun 1, 1987

Showing the 10 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Dec 30, 1985Planned (H) · Complete scope, Safety#18074211$3,0006 viol.

Inspection #18074211

Dates

Opened
Dec 30, 1985
Closing Conference Date
Dec 31, 1985
Contested
Feb 3, 1986
Final Order
Jul 9, 1986
Closed
Mar 24, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
10

Violations and Penalties

Total Violations
6
Violation Types
1 repeat, 5 other-than-serious
Initial Penalties
$6,000
Penalties on Record
$3,000
Site Address
70th St. & Essington Ave., Philadelphia, PA 19153
Industry
238140 Masonry Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Repeat11$6,000$3,000Jan 30, 1986Feb 3, 1986Jul 9, 1986
020011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other110$0$0Jan 30, 1986-Jul 9, 1986
020021926.21
Safety Training and Education
OSHA citation code: 19260021 B02
Other110$0$0Jan 30, 1986-Jul 9, 1986
020031926.50
Medical Services and First Aid (Construction)
OSHA citation code: 19260050 B
Other110$0$0Jan 30, 1986-Jul 9, 1986
020041926.50
Medical Services and First Aid (Construction)
OSHA citation code: 19260050 E
Other110$0$0Jan 30, 1986-Jul 9, 1986
020051926.50
Medical Services and First Aid (Construction)
OSHA citation code: 19260050 F
Other110$0$0Jan 30, 1986-Jul 9, 1986
Jul 29, 1985Planned (H) · Complete scope, Safety#711218$7009 viol.

Inspection #711218

Dates

Opened
Jul 29, 1985
Closing Conference Date
Jul 30, 1985
Closed
Jun 12, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
2

Violations and Penalties

Total Violations
9
Violation Types
3 serious, 6 other-than-serious
Initial Penalties
$700
Penalties on Record
$700
Site Address
70th St. & Essington Ave., Philadelphia, PA 19153
Industry
238140 Masonry Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 B08
Serious42$210$210Aug 30, 1985--
010021926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 C01
Serious32$210$210Aug 30, 1985--
010031926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 D
Serious12$280$280Aug 30, 1985--
020011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other12$0$0Aug 30, 1985--
020021926.24
Fire Protection and Prevention
Other12$0$0Aug 30, 1985--
020031926.50
Medical Services and First Aid (Construction)
OSHA citation code: 19260050 E
Other12$0$0Aug 30, 1985--
020041926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 I
Other42$0$0Aug 30, 1985--
020051926.250
General Requirements for Storage
OSHA citation code: 19260250 A02
Other22$0$0Aug 30, 1985--
020061926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 H01
Other42$0$0Aug 30, 1985--
Aug 15, 1983Planned (H) · Complete scope, Safety#12768792$5007 viol.

Inspection #12768792

Dates

Opened
Aug 15, 1983
Closing Conference Date
Aug 16, 1983
Closed
Mar 29, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
27

Violations and Penalties

Total Violations
7
Violation Types
7 serious
Initial Penalties
$2,790
Penalties on Record
$500
Site Address
Executive House City Line & Ov, Philadelphia, PA 19131
Industry
238140 Masonry Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.28
Personal Protective Equipment
OSHA citation code: 19260028 A
Serious2-$540$100Sep 5, 1983--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 H15
Serious2-$540$100Sep 8, 1983--
010031926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 D01
Serious4-$540$100Sep 8, 1983--
010041926.552
Material Hoists, Personnel Hoists, and Elevators
OSHA citation code: 19260552 B02
Serious1-$540$100Sep 8, 1983--
01005A1926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 F01
Serious3-$630$100Sep 8, 1983--
01005B1926.56
Illumination
OSHA citation code: 19260056 A
Serious1-$0$0Sep 8, 1983--
01005C1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 D
Serious3-$0$0Sep 8, 1983--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements8 citations · $14,600
1926.500Fall Protection - Scope, Application, and Definitions5 citations · $1,220
1926.50Medical Services and First Aid (Construction)4 citations · $0

Industry comparison

Violations per inspection
This employer9.0
Industry average2.1
Penalties per inspection
This employer$4,160
Industry average$2,530

Specialty Trade Contractors, 551,694 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: masonry contractors reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 15.2%; NAICS 23814 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in PHILADELPHIA, PA

All employers in PHILADELPHIA →