Skip to content
SafetyRecord logoSafetyRecord
HARDY DEVELOPMENT INC
$3,250
penalties
23
viol.
5
insp.

HARDY DEVELOPMENT INC

900 RHODE ISLAND AVE NW, WASHINGTON, DC 20001NAICS 238140 Masonry Contractors

Inspections
5
Aug 2001 to May 2011 · 5 safety, 0 health
Violations
23
across 5 inspections
Penalties on record
$3,250
latest amounts in DOL records
By classification
Serious 14Willful 0Repeat 0Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 12, 2011Planned (H) · Complete scope, Safety#315550707$03 viol.

Inspection #315550707

Dates

Opened
May 12, 2011
Closing Conference Date
May 12, 2011
Closed
Jul 11, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$4,200
Penalties on Record
$0
Site Address
1600 8th Street Nw, Washington, DC 20001
Industry
236118 Residential Remodelers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B04 II
Other14$1,800$0Jun 21, 2011--
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Other12$2,400$0Jun 21, 2011--
020011926.95
Criteria for Personal Protective Equipment (Construction)
OSHA citation code: 19260095 A
Other13$0$0Jun 10, 2011--
Jan 25, 2011Planned (H) · Complete scope, Safety#315196733$7007 viol.

Inspection #315196733

Dates

Opened
Jan 25, 2011
Closing Conference Date
Jan 25, 2011
Closed
Apr 8, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
7
Violation Types
1 serious, 6 other-than-serious
Initial Penalties
$6,600
Penalties on Record
$700
Site Address
1600 8th Street, Nw, Washington, DC 20001
Industry
236118 Residential Remodelers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 B02
Serious15$3,300$700Mar 20, 2011--
01001B1926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 H
Other15$0$0Mar 24, 2011--
01001C1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Other15$0$0Mar 20, 2011--
01001D1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 J01 I
Other13$0$0Mar 20, 2011--
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Other12$3,300$0Mar 20, 2011--
020011926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01 I
Other15$0$0Mar 20, 2011--
020021926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01 II
Other13$0$0Mar 20, 2011--
Aug 30, 2006Referral (C) · Complete scope, Safety#310221387$5001 viol.

Inspection #310221387

Dates

Opened
Aug 30, 2006
Closing Conference Date
Aug 30, 2006
Closed
Oct 11, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$625
Penalties on Record
$500
Site Address
1000 Rhode Island Ave Nw, Washington, DC 20006
Industry
238140 Masonry Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B03
Serious12$625$500Sep 12, 2006--
Aug 9, 2006Referral (C) · Complete scope, Safety#310221023$1,3008 viol.

Inspection #310221023

Dates

Opened
Aug 9, 2006
Closing Conference Date
Aug 9, 2006
Closed
Oct 13, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7
Related Activity
1 referral

Violations and Penalties

Total Violations
8
Violation Types
8 serious
Initial Penalties
$2,400
Penalties on Record
$1,300
Site Address
1000 Rhode Island Ave Nw, Washington, DC 20006
Industry
238140 Masonry Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.102
Eye and Face Protection (Construction)
OSHA citation code: 19260102 A01
Serious11$450$250Aug 21, 2006--
01002A1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 II
Serious11$450$250Aug 21, 2006--
01002B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B02
Serious11$0$0Aug 21, 2006--
01003A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B05 I
Serious11$1,500$800Aug 21, 2006--
01003B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious14$0$0Aug 21, 2006--
01003C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F03
Serious15$0$0Aug 22, 2006--
01003D1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious15$0$0Aug 21, 2006--
01003E1926.454
Scaffolding - Training
OSHA citation code: 19260454 A
Serious15$0$0Aug 22, 2006--
Aug 31, 2001Referral (C) · Complete scope, Safety#303856892$7504 viol.

Inspection #303856892

Dates

Opened
Aug 31, 2001
Closing Conference Date
Aug 31, 2001
Closed
Sep 26, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$0
Penalties on Record
$750
Site Address
900 Rhode Island Ave Nw, Washington, DC 20001
Industry
238140 Masonry Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01005A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Serious11$0$750Sep 12, 2001--
01005B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious11$0$0Sep 12, 2001--
01005C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious11$0$0Sep 12, 2001--
01005D1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious11$0$0Sep 12, 2001--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements7 citations · $1,550
1926.501Fall Protection - Duty to Have Fall Protection5 citations · $500
1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $250

Industry comparison

Violations per inspection
This employer4.6
Industry average2.1
Penalties per inspection
This employer$650
Industry average$2,542

Specialty Trade Contractors, 558,086 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in WASHINGTON, DC