Skip to content
SafetyRecord logoSafetyRecord
INSITE CONSTRUCTION, INC.
$32,506
penalties
20
viol.
7
insp.

INSITE CONSTRUCTION, INC.

3200 CAPRI DRIVE, PHILADELPHIA, PA 19146NAICS 236116 New Multifamily Housing Construction (except For-Sale Builders)

Inspections
7
Feb 2017 to Aug 2021 · 6 safety, 1 health
Violations
20
across 7 inspections
Penalties on record
$32,506
latest amounts in DOL records
By classification
Serious 13Willful 0Repeat 0Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 12, 2021Programmed Related (I) · Partial scope, Safety#345533608$00 viol.

Inspection #345533608

Dates

Opened
Aug 12, 2021
Closing Conference Date
Aug 12, 2021
Closed
Sep 30, 2021

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2500 E Tioga St, Philadelphia, PA 19134
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Jun 2, 2021Planned (H) · Complete scope, Safety#345340764$00 viol.

Inspection #345340764

Dates

Opened
Jun 2, 2021
Closing Conference Date
Jun 2, 2021
Closed
Nov 3, 2021

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2500 E Tioga St, Philadelphia, PA 19134
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 23, 2020Complaint (B) · Partial scope, Safety#345024236$4,3452 viol.

Inspection #345024236

Dates

Opened
Jul 23, 2020
Closing Conference Date
Jul 23, 2020
Final Order
Mar 17, 2021
Closed
Jan 25, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$5,793
Penalties on Record
$4,345
Site Address
3200 Capri Drive, Philadelphia, PA 19145
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 II I
Serious14$3,218$2,414Feb 18, 2021-Mar 17, 2021
01002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B02
Serious11$2,575$1,931Feb 18, 2021-Mar 17, 2021
Jun 15, 2020Referral (C) · Partial scope, Safety#344792395$13,3567 viol.

Inspection #344792395

Dates

Opened
Jun 15, 2020
Closing Conference Date
Jun 15, 2020
Final Order
Jan 7, 2021
Closed
Jan 10, 2025

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15
Related Activity
1 referral

Violations and Penalties

Total Violations
7
Violation Types
7 serious
Initial Penalties
$17,811
Penalties on Record
$13,356
Site Address
2700 East Auburn Street, Philadelphia, PA 19134
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F03
Serious13$5,937$4,452Dec 23, 2020-Jan 7, 2021
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02
Serious13$0$0Dec 23, 2020-Jan 7, 2021
01001C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious13$0$0Dec 23, 2020-Jan 7, 2021
01001D1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G04 I
Serious13$0$0Dec 23, 2020-Jan 7, 2021
01002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Serious13$5,937$4,452Dec 23, 2020-Jan 7, 2021
01002B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 H01
Serious13$0$0Dec 23, 2020-Jan 7, 2021
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Serious13$5,937$4,452Dec 23, 2020-Jan 7, 2021
May 15, 2020Complaint (B) · Partial scope, Safety#344752688$4,0482 viol.

Inspection #344752688

Dates

Opened
May 15, 2020
Closing Conference Date
May 15, 2020
Final Order
Jan 7, 2021
Closed
Sep 3, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$4,048
Penalties on Record
$4,048
Site Address
3200 Capri Drive, Philadelphia, PA 19145
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 VII
Serious14$4,048$4,048-Jan 7, 2021
01001B1926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious14$0$0Dec 7, 2020-Jan 7, 2021
Jan 6, 2020Planned (H) · Partial scope, Safety#344540760$4,0482 viol.

Inspection #344540760

Dates

Opened
Jan 6, 2020
Closing Conference Date
Jan 6, 2020
Final Order
Jul 27, 2020
Closed
Sep 4, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$4,048
Penalties on Record
$4,048
Site Address
3200 Capri Drive, Philadelphia, PA 19145
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious13$4,048$4,048-Jul 27, 2020
01001B1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Serious13$0$0Aug 17, 2020-Jul 27, 2020
Feb 2, 2017Complaint (B) · Partial scope, Health#342076437$6,7097 viol.

Inspection #342076437

Dates

Opened
Feb 2, 2017
Closing Conference Date
Feb 2, 2017
Final Order
Jul 20, 2017
Closed
Sep 9, 2019

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
10
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
7 other-than-serious
Initial Penalties
$10,322
Penalties on Record
$6,709
Site Address
1501 S. 17th Street, Philadelphia, PA 19146
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A03 II
Other12$2,716$1,765Jul 10, 2017-Jul 20, 2017
01001C1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 III
Other110$0$0Jul 10, 2017-Jul 20, 2017
01001D1926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Other22$0$0Jul 10, 2017-Jul 20, 2017
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Other210$3,803$2,472Jul 10, 2017-Jul 20, 2017
01003A1926.1101
Asbestos (Construction)
OSHA citation code: 19261101 K03 I
Other10010$3,803$2,472-Jul 20, 2017
01003B1926.1101
Asbestos (Construction)
OSHA citation code: 19261101 K03 II B
Other10010$0$0Jul 10, 2017-Jul 20, 2017
01003C1926.1101
Asbestos (Construction)
OSHA citation code: 19261101 K08 III
Other10010$0$0-Jul 20, 2017
Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements9 citations · $19,335
1926.1101Asbestos (Construction)3 citations · $2,472
1926.405Electrical - Wiring Methods (Construction)2 citations · $2,414

Industry comparison

Violations per inspection
This employer2.9
Industry average1.5
Penalties per inspection
This employer$4,644
Industry average$1,285

Construction of Buildings, 202,638 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: residential building construction reported 2.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 8.5%; NAICS 2361 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in PHILADELPHIA, PA

All employers in PHILADELPHIA →