JOHN ZARBOCK PLUMBING INC.
2818 W PARKWAY BLVD, West Valley City, UT 84119 · NAICS 238220 Plumbing, Heating, and Air-Conditioning Contractors
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jun 4, 2007#310455969Jun 4, 2007Planned (H) · Complete scope, Safety#310455969$6257 viol.7 violations$625 in penalties
Inspection #310455969
Dates
- Opened
- Jun 4, 2007
- Closing Conference Date
- Jun 11, 2007
- Closed
- Aug 28, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 4
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 5 serious, 2 other-than-serious
- Initial Penalties
- $4,750
- Penalties on Record
- $625
- Site Address
- 2818 W Parkway Blvd, West Valley City, UT 84119
- Industry
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1926.651 Excavations - Specific Excavation Requirements OSHA citation code: 19260651 C02 | Serious | 1 | 3 | $1,500 | $200 | Jul 13, 2007 | - | - |
| 01001B | 1926.651 Excavations - Specific Excavation Requirements OSHA citation code: 19260651 H01 | Serious | 1 | 3 | $0 | $0 | Jul 13, 2007 | - | - |
| 01001C | 1926.651 Excavations - Specific Excavation Requirements OSHA citation code: 19260651 J02 | Serious | 1 | 3 | $0 | $0 | Jul 13, 2007 | - | - |
| 01002 | 1926.652 Excavations - Protection of Employees OSHA citation code: 19260652 A01 | Serious | 1 | 3 | $1,500 | $200 | Jul 13, 2007 | - | - |
| 01003 | 1926.651 Excavations - Specific Excavation Requirements OSHA citation code: 19260651 K01 | Serious | 1 | 3 | $1,500 | $200 | Jul 13, 2007 | - | - |
| 02001 | 1904.29 Forms OSHA citation code: 19040029 A | Other | 1 | 3 | $250 | $25 | Aug 13, 2007 | - | - |
| 02002 | 1910.134 Respiratory Protection OSHA citation code: 19100134 C02 I | Other | 1 | 3 | $0 | $0 | Aug 13, 2007 | - | - |
May 23, 2007#310455738May 23, 2007Planned (H) · Partial scope, Safety#310455738$6004 viol.4 violations$600 in penalties
Inspection #310455738
Dates
- Opened
- May 23, 2007
- Closing Conference Date
- May 23, 2007
- Closed
- Aug 6, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 2
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 other-than-serious
- Initial Penalties
- $4,500
- Penalties on Record
- $600
- Site Address
- 4100 S 3200 W., West Valley City, UT 84119
- Industry
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.651 Excavations - Specific Excavation Requirements OSHA citation code: 19260651 J02 | Serious | 1 | 2 | $1,500 | $200 | Jul 31, 2007 | - | - |
| 01002 | 1926.651 Excavations - Specific Excavation Requirements OSHA citation code: 19260651 K01 | Serious | 1 | 2 | $1,500 | $200 | Jul 31, 2007 | - | - |
| 01003 | 1926.652 Excavations - Protection of Employees OSHA citation code: 19260652 A01 | Serious | 1 | 2 | $1,500 | $200 | Jul 31, 2007 | - | - |
| 02001 | 1926.1053 Ladders (Construction) OSHA citation code: 19261053 B01 | Other | 1 | 2 | $0 | $0 | Jul 31, 2007 | - | - |
Sep 26, 2000#303610430Sep 26, 2000Planned (H) · Complete scope, Safety#303610430$1,6253 viol.3 violations$1,625 in penalties
Inspection #303610430
Dates
- Opened
- Sep 26, 2000
- Closing Conference Date
- Sep 26, 2000
- Closed
- Dec 15, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 2 serious, 1 other-than-serious
- Initial Penalties
- $1,625
- Penalties on Record
- $1,625
- Site Address
- 5800 W 2100 S, Suite H, I & J, West Valley City, UT 84120
- Industry
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001B | 10005 OSHA citation code: 10005 D04 | Serious | 1 | 1 | $0 | $0 | Dec 11, 2000 | - | - |
| 01002 | 1926.21 Safety Training and Education OSHA citation code: 19260021 B02 | Serious | 1 | 1 | $1,625 | $1,625 | Dec 11, 2000 | - | - |
| 02001 | 10008 OSHA citation code: 10008 C01 | Other | 1 | 1 | $0 | $0 | Dec 13, 2000 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
3 inspections, 2000 to 2007. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Industry comparison
Specialty Trade Contractors, 552,207 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: plumbing, heating, and air-conditioning contractors reported 3.0 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.2%; NAICS 23822 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source