LATEX INTERNATIONAL, LLC
12 COMMERCE DR, SHELTON, CT 06484 · NAICS 325211 Plastics Material and Resin Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jun 30, 2010#314440363Jun 30, 2010Planned (H) · Complete scope, Safety#314440363$9,36015 viol.15 violations$9,360 in penalties
Inspection #314440363
Dates
- Opened
- Jun 30, 2010
- Closing Conference Date
- Jun 30, 2010
- Closed
- Jan 12, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 151
Violations and Penalties
- Total Violations
- 15
- Violation Types
- 11 serious, 4 other-than-serious
- Initial Penalties
- $14,400
- Penalties on Record
- $9,360
- Site Address
- 510 River Rd, Shelton, CT 06484
- Industry
- 326299 All Other Rubber Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (15 of 15 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 B01 | Serious | 1 | 1 | $1,200 | $780 | Dec 16, 2010 | - | - |
| 01002 | 1910.23 Ladders OSHA citation code: 19100023 B01 I | Serious | 1 | 1 | $1,600 | $1,040 | Dec 16, 2010 | - | - |
| 01003A | 1910.23 Ladders OSHA citation code: 19100023 C03 | Serious | 1 | 3 | $1,200 | $780 | Dec 16, 2010 | - | - |
| 01003B | 1910.23 Ladders OSHA citation code: 19100023 D01 III | Serious | 2 | 2 | $0 | $0 | Dec 16, 2010 | - | - |
| 01004 | 1910.145 Specifications for Accident Prevention Signs and Tags OSHA citation code: 19100145 C02 I | Serious | 1 | 2 | $1,200 | $780 | Dec 16, 2010 | - | - |
| 01005 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 2 | $1,600 | $1,040 | Dec 16, 2010 | - | - |
| 01006 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 1 | $2,000 | $1,300 | Jan 5, 2011 | - | - |
| 01007 | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B02 II | Serious | 1 | 3 | $1,600 | $1,040 | Dec 16, 2010 | - | - |
| 01008A | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F01 IV | Serious | 1 | 2 | $1,200 | $780 | Dec 16, 2010 | - | - |
| 01008B | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 | Serious | 1 | 1 | $0 | $0 | Dec 16, 2010 | - | - |
| 01009 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Serious | 1 | 2 | $1,200 | $780 | Dec 16, 2010 | - | - |
| 02001A | 1904.32 Annual Summary OSHA citation code: 19040032 B03 | Other | 1 | - | $800 | $520 | Jan 5, 2011 | - | - |
| 02001B | 1904.29 Forms OSHA citation code: 19040029 B01 | Other | 2 | 1 | $0 | $0 | Jan 5, 2011 | - | - |
| 02002 | 1904.29 Forms OSHA citation code: 19040029 B01 | Other | 2 | 1 | $800 | $520 | Jan 5, 2011 | - | - |
| 02003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 III | Other | 1 | 1 | $0 | $0 | Dec 16, 2010 | - | - |
May 2, 2007#310541685May 2, 2007Complaint (B) · Partial scope, Safety#310541685$15,90023 viol.23 violations$15,900 in penalties
Inspection #310541685
Dates
- Opened
- May 2, 2007
- Closing Conference Date
- Jun 6, 2007
- Closed
- Aug 27, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 285
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 23
- Violation Types
- 20 serious, 3 other-than-serious
- Initial Penalties
- $23,050
- Penalties on Record
- $15,900
- Site Address
- 510 River Rd, Shelton, CT 06484
- Industry
- 326299 All Other Rubber Product Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Ammonia | 14 | 0.451933 - 97.707057 | ppm |
Violations
Violation list (16 of 23 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Serious | 2 | 3 | $1,700 | $1,200 | Aug 13, 2007 | - | - |
| 01002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVD | Serious | 1 | 2 | $1,275 | $900 | Aug 14, 2007 | - | - |
| 01003A | 1910.111 Storage and Handling of Anhydrous Ammonia OSHA citation code: 19100111 B10 II | Serious | 2 | 1 | $1,275 | $1,000 | Jul 30, 2007 | - | - |
| 01003B | 1910.111 Storage and Handling of Anhydrous Ammonia OSHA citation code: 19100111 B10 III | Serious | 2 | 1 | $0 | $0 | Aug 29, 2007 | - | - |
| 01004A | 1910.119 Process Safety Management of Highly Hazardous Chemicals OSHA citation code: 19100119 G01 I | Serious | 1 | 9 | $2,125 | $1,500 | Aug 29, 2007 | - | - |
| 01004B | 1910.119 Process Safety Management of Highly Hazardous Chemicals OSHA citation code: 19100119 G03 | Serious | 1 | 3 | $0 | $0 | Aug 29, 2007 | - | - |
| 01006A | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D02 | Serious | 1 | 3 | $1,275 | $900 | Aug 29, 2007 | - | - |
| 01006B | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 F01 | Serious | 1 | 5 | $0 | $0 | Aug 29, 2007 | - | - |
| 01007A | 1910.134 Respiratory Protection OSHA citation code: 19100134 D01 I | Serious | 1 | 2 | $2,975 | $2,000 | Oct 1, 2007 | - | - |
| 01007B | 1910.1000 Air Contaminants OSHA citation code: 19101000 A02 | Serious | 1 | 2 | $0 | $0 | Oct 1, 2007 | - | - |
| 01007C | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 1 | 2 | $0 | $0 | Oct 1, 2007 | - | - |
| 01008 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 2 | $2,975 | $1,600 | Aug 29, 2007 | - | - |
| 01009 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 P01 | Other | 2 | 6 | $1,500 | $0 | Aug 14, 2007 | - | - |
| 01012 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 E01 IV | Serious | 2 | 1 | $1,275 | $900 | Aug 29, 2007 | - | - |
| 01013A | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 2 | 3 | $1,700 | $1,000 | Aug 2, 2007 | - | - |
| 01013B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 II | Serious | 1 | 2 | $0 | $0 | Aug 2, 2007 | - | - |
Showing the 16 violations listed first by citation identifier. This inspection has 23 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 9, 2007#310920970Jan 9, 2007Complaint (B) · Partial scope, Safety#310920970$6,00010 viol.10 violations$6,000 in penalties
Inspection #310920970
Dates
- Opened
- Jan 9, 2007
- Closing Conference Date
- Jan 10, 2007
- Closed
- Jul 23, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 285
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 6 serious, 4 other-than-serious
- Initial Penalties
- $10,000
- Penalties on Record
- $6,000
- Site Address
- 12 Commerce Dr, Shelton, CT 06484
- Industry
- 325211 Plastics Material and Resin Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (10 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Serious | 1 | 2 | $2,000 | $1,200 | Jul 19, 2007 | - | - |
| 01002 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 2 | 2 | $2,000 | $1,200 | Jul 25, 2007 | - | - |
| 01003A | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 II | Serious | 1 | 3 | $3,500 | $2,100 | Jul 25, 2007 | - | - |
| 01003B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Serious | 2 | 2 | $0 | $0 | Jul 25, 2007 | - | - |
| 01004A | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 I | Serious | 1 | 3 | $1,500 | $900 | Aug 8, 2007 | - | - |
| 01004B | 1910.1200 Hazard Communication OSHA citation code: 19101200 H02 III | Serious | 1 | 3 | $0 | $0 | Aug 8, 2007 | - | - |
| 02001 | 1904.29 Forms OSHA citation code: 19040029 B01 | Other | 6 | 1 | $1,000 | $600 | Aug 8, 2007 | - | - |
| 02002 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 A04 | Other | 6 | 3 | $0 | $0 | Aug 8, 2007 | - | - |
| 02003 | 1910.38 Emergency Action Plans OSHA citation code: 19100038 E | Other | 1 | 3 | $0 | $0 | Aug 8, 2007 | - | - |
| 02004 | 1910.134 Respiratory Protection OSHA citation code: 19100134 K06 | Other | 2 | 2 | $0 | $0 | Aug 8, 2007 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
3 inspections, 2007 to 2010. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Industry comparison
Chemical Manufacturing, 12,274 employers with OSHA inspections. Arithmetic from DOL records.