Skip to content
SafetyRecord logoSafetyRecord
MADISON CONCRETE CONSTRUCTION COMPANY
$24,347
penalties
18
viol.
15
insp.

MADISON CONCRETE CONSTRUCTION COMPANY

CONSTITUTION CENTER, 5TH & RACE, PHILADELPHIA, PA 19153NAICS 238140 Masonry Contractors

Inspections
15
Aug 1993 to Feb 2016 · 13 safety, 2 health
Violations
18
across 15 inspections
Penalties on record
$24,347
latest amounts in DOL records
By classification
Serious 13Willful 0Repeat 1Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 20, 1998Programmed Related (I) · Partial scope, Safety#301447751$4,5606 viol.

Inspection #301447751

Dates

Opened
Feb 20, 1998
Closing Conference Date
Feb 23, 1998
Contested
Mar 30, 1998
Final Order
Sep 26, 1998
Closed
Oct 27, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
26

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$7,600
Penalties on Record
$4,560
Site Address
718 Arch Street, Suite 101-S, Philadelphia, PA 19106
Industry
238140 Masonry Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious12$2,000$1,200Mar 27, 1998Mar 30, 1998Sep 26, 1998
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B05
Serious11$2,000$1,200Mar 27, 1998Mar 30, 1998Sep 26, 1998
01003A1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 B04
Serious11$2,000$1,200Mar 27, 1998Mar 30, 1998Sep 26, 1998
01003B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 B05
Serious11$0$0Mar 27, 1998Mar 30, 1998Sep 26, 1998
01003C1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 B09
Other11$0$0Mar 27, 1998Mar 30, 1998Sep 26, 1998
010041926.1053
Ladders (Construction)
OSHA citation code: 19261053 B16
Serious11$1,600$960Mar 27, 1998Mar 30, 1998Sep 26, 1998
Oct 31, 1997Unprogrammed Related (G) · Partial scope, Safety#301447074$1,8003 viol.

Inspection #301447074

Dates

Opened
Oct 31, 1997
Closing Conference Date
Oct 31, 1997
Contested
Dec 8, 1997
Final Order
May 4, 1998
Closed
May 4, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
4

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$3,600
Penalties on Record
$1,800
Site Address
9000 Tinicum Avenue, Philadelphia, PA 19153
Industry
238140 Masonry Contractors

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious11$2,000$1,000Dec 4, 1997Dec 8, 1997May 4, 1998
01002A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious13$1,600$800Dec 4, 1997Dec 8, 1997May 4, 1998
01002B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious13$0$0Dec 4, 1997Dec 8, 1997May 4, 1998
May 2, 1996Programmed Related (I) · Partial scope, Safety#102943321$7001 viol.

Inspection #102943321

Dates

Opened
May 2, 1996
Closing Conference Date
May 6, 1996
Contested
May 23, 1996
Final Order
Sep 12, 1996
Closed
Oct 16, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
6

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$1,300
Penalties on Record
$700
Site Address
718 Arch Street, Suite 101-S, Philadelphia, PA 19106
Industry
238140 Masonry Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.102
Eye and Face Protection (Construction)
OSHA citation code: 19260102 A01
Serious11$1,300$700May 25, 1996May 23, 1996Sep 12, 1996
Jan 9, 1995Programmed Related (I) · Partial scope, Safety#102937208$1001 viol.

Inspection #102937208

Dates

Opened
Jan 9, 1995
Closing Conference Date
Jan 18, 1995
Contested
Mar 6, 1995
Final Order
Jul 14, 1995
Closed
Oct 11, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
25

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$525
Penalties on Record
$100
Site Address
Spectrum Ii Broad & Patterson Ave, Philadelphia, PA 19148
Industry
238140 Masonry Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.102
Eye and Face Protection (Construction)
OSHA citation code: 19260102 A01
Serious11$525$100Feb 27, 1995Mar 6, 1995Jul 14, 1995
Aug 6, 1993Planned (H) · Complete scope, Safety#18002683$01 viol.

Inspection #18002683

Dates

Opened
Aug 6, 1993
Closing Conference Date
Aug 6, 1993
Contested
Nov 22, 1993
Final Order
Jun 24, 1994
Closed
Jun 21, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
36th & Market Street, Philadelphia, PA 19104
Industry
238140 Masonry Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.701
Concrete and Masonry Construction - General Requirements
OSHA citation code: 19260701 B
Other12$0$0Nov 16, 1993Nov 22, 1993Jun 24, 1994
Inspections 11 to 15 of 15, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.501Fall Protection - Duty to Have Fall Protection4 citations · $3,500
1926.1053Ladders (Construction)3 citations · $1,760
1926.502Fall Protection Systems Criteria and Practices3 citations · $1,200

Industry comparison

Violations per inspection
This employer1.2
Industry average2.1
Penalties per inspection
This employer$1,623
Industry average$2,540

Specialty Trade Contractors, 559,279 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in PHILADELPHIA, PA

All employers in PHILADELPHIA →