Skip to content
SafetyRecord logoSafetyRecord
NAVAL AIR REWORK FACILITY
$0
penalties
18
viol.
2
insp.

NAVAL AIR REWORK FACILITY

NAVAL AIR STATION, PENSACOLA, FL 32508

Inspections
2
Apr 1986 to Apr 1986 · 1 safety, 1 health
Violations
18
across 2 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 1, 1986Planned (H) · Complete scope, Health#101778660$011 viol.

Inspection #101778660

Dates

Opened
Apr 1, 1986
Closing Conference Date
Apr 24, 1986
Closed
Apr 9, 1987

Inspection

Advance Notice
Yes
Owner Type
Federal
Union Status
Yes
Number of Employees
3,940

Violations and Penalties

Total Violations
11
Violation Types
2 serious, 9 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Naval Air Station, Pensacola, FL 32508
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling21 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
1,1,2-Trichloro-1,2,2-Trifluoroethane40 - 252ppm
2-Butanone1558ppm
Antimony and Compounds (as Sb)50 - 0.0149mg/m³
Beryllium and Beryllium Compounds (as Be)50mg/m³
Cadmium Fume (as Cd)50 - 0.0043mg/m³
Chromic Acid and Chromates (as CrO3)30mg/m³
Chromium, Metal and Insoluble Salts50 - 0.049mg/m³
Cobalt, Metal, Dust and Fume (as Co)50mg/m³
Copper Fume (as Cu)50 - 0.0077mg/m³
Iron Oxide Fume50 - 3.5092mg/m³
Lead, Inorganic (as Pb)80 - 0.0376mg/m³
Manganese Fume (as Mn)50 - 0.2146mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)50mg/m³
Nickel, Metal and Insoluble compounds (as Ni)50 - 0.005mg/m³
Particulates not otherwise regulated (Respirable Fraction)100mg/m³
Particulates not otherwise regulated (Total Dust)30mg/m³
Stoddard Solvent40 - 90.7
Tin, inorganic compounds (except oxides) (as Sn)30mg/m³
Toluene1306ppm
Vanadium fume (as V2O5)50mg/m³
Zinc Oxide Fume50 - 0.0277mg/m³

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 I
Serious36$0$0Sep 16, 1987--
01001B1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 III
Other16$0$0Oct 12, 1986--
01001C1910.106
Flammable Liquids
OSHA citation code: 19100106 E05 I
Serious13$0$0Sep 13, 1986--
020011910.94
Ventilation
OSHA citation code: 19100094 A04 I
Other25$0$0Oct 12, 1986--
020021910.94
Ventilation
OSHA citation code: 19100094 D09 IX
Other14$0$0Oct 12, 1986--
020031910.94
Ventilation
OSHA citation code: 19100094 D09 VIII
Other18$0$0Sep 13, 1986--
020041910.95
Occupational Noise Exposure
OSHA citation code: 19100095 L01
Other120$0$0Sep 13, 1986--
020051910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Other320$0$0Oct 12, 1986--
020061910.1025
Lead
OSHA citation code: 19101025 L01 I
Other16$0$0Oct 12, 1986--
020071910.134
Respiratory Protection
OSHA citation code: 19100134 C
Other13$0$0Sep 17, 1986--
020081960.67
Federal Agency Certification of the Injury and Illness Annual Summary
OSHA citation code: 19600067 B
Other1940$0$0Oct 12, 1986--
Apr 1, 1986Planned (H) · Complete scope, Safety#100340603$07 viol.

Inspection #100340603

Dates

Opened
Apr 1, 1986
Closing Conference Date
Apr 10, 1986
Closed
Nov 21, 1990

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
3,940

Violations and Penalties

Total Violations
7
Violation Types
5 serious, 2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Naval Air Station, Pensacola, FL 32508
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021910.28
Duty to Have Fall Protection
OSHA citation code: 19100028 A01
Serious322$0$0Feb 1, 1987--
010041910.29
Fall Protection Systems and Criteria
OSHA citation code: 19100029 F04 I
Serious115$0$0Feb 1, 1987--
010101910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious725$0$0Feb 1, 1987--
010121910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious24398$0$0Feb 1, 1987--
010211910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 C02 IV
Serious23$0$0Feb 1, 1987--
010561910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IVC
Other22$0$0Feb 1, 1987--
010621910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05
Other11$0$0Feb 1, 1987--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.106Flammable Liquids3 citations · $0
1910.94Ventilation3 citations · $0
1910.212General Requirements for All Machines (Machine Guarding)2 citations · $0

Chemical exposure sampling

Samples
97
Substances
21
Inspections
1

Other inspected employers in PENSACOLA, FL

All employers in PENSACOLA →