Skip to content
SafetyRecord logoSafetyRecord
PERFECT PATTERNS INC
$13,940
penalties
27
viol.
5
insp.

PERFECT PATTERNS INC

2221 E. PENSAR AVE., Appleton, WI 54915

Inspections
5
Dec 1986 to Nov 2014 · 3 safety, 2 health
Violations
27
across 5 inspections
Penalties on record
$13,940
latest amounts in DOL records
By classification
Serious 19Willful 0Repeat 0Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 25, 2014Referral (C) · Partial scope, Safety#340103167$4901 viol.

Inspection #340103167

Dates

Opened
Nov 25, 2014
Closing Conference Date
Nov 25, 2014
Final Order
Feb 17, 2015
Closed
Feb 17, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$700
Penalties on Record
$490
Site Address
1325 S. Perkins, Appleton, WI 54914
Industry
333514 Special Die and Tool, Die Set, Jig, and Fixture Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011904.29
Forms
OSHA citation code: 19040029 B01
Other65$700$490Feb 6, 2015-Feb 17, 2015
Dec 7, 2011Complaint (B) · Partial scope, Safety#331098913$01 viol.

Inspection #331098913

Dates

Opened
Dec 7, 2011
Closing Conference Date
Dec 7, 2011
Final Order
Jan 18, 2012
Closed
Jan 19, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
70
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
3035 N. Roemer Rd., Appleton, WI 54911
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G01 IV A
Other-1$0$0Jan 18, 2012-Jan 18, 2012
Dec 7, 2011Complaint (B) · Partial scope, Health#331098624$11,50010 viol.

Inspection #331098624

Dates

Opened
Dec 7, 2011
Closing Conference Date
Dec 7, 2011
Final Order
Apr 18, 2012
Closed
Jun 18, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
35
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
9 serious, 1 other-than-serious
Initial Penalties
$20,195
Penalties on Record
$11,500
Site Address
3035 N. Roemer Rd., Appleton, WI 54911
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.94
Ventilation
OSHA citation code: 19100094 A02 II
Serious33$4,900$4,000Apr 14, 2014-Apr 18, 2012
01001B1910.94
Ventilation
OSHA citation code: 19100094 B05 IV
Serious66$0$0Apr 14, 2014-Apr 18, 2012
01001C1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious99$0$0Apr 14, 2014-Apr 18, 2012
01001D1910.1000
Air Contaminants
OSHA citation code: 19101000 C
Serious99$0$0Apr 14, 2014-Apr 18, 2012
01001E1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious99$0$0Apr 14, 2014-Apr 18, 2012
01002A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Serious44$4,900$4,000Apr 14, 2014-Apr 18, 2012
01002B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious55$4,900$0May 4, 2012-Apr 18, 2012
01002C1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious55$0$0May 4, 2012-Apr 18, 2012
010041910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious99$4,900$3,500Jun 24, 2012-Apr 18, 2012
020011910.132
General requirements
OSHA citation code: 19100132 D02
Other130$595$0Apr 16, 2012-Apr 18, 2012
Oct 2, 1992Planned (H) · Complete scope, Health#106506371$1,95013 viol.

Inspection #106506371

Dates

Opened
Oct 2, 1992
Closing Conference Date
Oct 7, 1992
Closed
Feb 24, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
28

Violations and Penalties

Total Violations
13
Violation Types
10 serious, 3 other-than-serious
Initial Penalties
$3,875
Penalties on Record
$1,950
Site Address
2221 E. Pensar Ave., Appleton, WI 54915
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Arsenic, Inorganic10mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Cadmium Fume (as Cd)20mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20mg/m³
Iron Oxide Fume20 - 0.1239mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20 - 0.0011mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20mg/m³

Violations

Violation list (10 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C05 IID
Serious128$675$350Jan 23, 1993--
01001B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 I
Serious128$0$0Jan 23, 1993--
01001C1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 II
Serious128$0$0Jan 23, 1993--
01001D1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 IV
Serious128$0$0Jan 23, 1993--
01001E1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 J04 IIE
Serious111$0$0Jan 23, 1993--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious111$675$325Oct 27, 1992--
01003A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious25$675$325Nov 2, 1992--
01003B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious25$0$0Oct 31, 1992--
010041910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious428$675$350Oct 31, 1992--
010051910.1200
Hazard Communication
OSHA citation code: 19101200 H02 II
Serious311$675$350Nov 24, 1992--

Showing the 10 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Dec 18, 1986Planned (H) · Partial scope, Safety#101729903$02 viol.

Inspection #101729903

Dates

Opened
Dec 18, 1986
Closing Conference Date
Dec 18, 1986
Closed
Feb 20, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
32

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1400 N. Ballard Road, Appleton, WI 54915
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other13$0$0Feb 23, 1987--
010021910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other13$0$0Feb 23, 1987--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication6 citations · $1,025
1910.147The control of hazardous energy (lockout/tagout)4 citations · $350
1910.95Occupational Noise Exposure3 citations · $4,000

Chemical exposure sampling

Samples
26
Substances
14
Inspections
1

Other inspected employers in Appleton, WI