Skip to content
SafetyRecord logoSafetyRecord
PIERCE HOMES OF CAROLINA, INC., LLC
$2,220
penalties
7
viol.
3
insp.

PIERCE HOMES OF CAROLINA, INC., LLC

153 BUIST AVE., Greenville, SC 29609NAICS 236116 New Multifamily Housing Construction (except For-Sale Builders)

Inspections
3
Sep 2002 to Dec 2003 · 3 safety, 0 health
Violations
7
across 3 inspections
Penalties on record
$2,220
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 2, 2003Planned (H) · Complete scope, Safety#306836495$02 viol.

Inspection #306836495

Dates

Opened
Dec 2, 2003
Closing Conference Date
Dec 22, 2003
Closed
Jan 21, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
153 Buist Ave., Greenville, SC 29609
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
030011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Serious14$0$0Jan 12, 2004--
040011926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01
Other24$0$0Jan 20, 2004--
Nov 14, 2003Unprogrammed Related (G) · Complete scope, Safety#306833997$1,9203 viol.

Inspection #306833997

Dates

Opened
Nov 14, 2003
Closing Conference Date
Dec 22, 2003
Closed
Feb 13, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1
Related Activity
1 accident

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$4,800
Penalties on Record
$1,920
Site Address
102 Oakhurst Avenue, Greenville, SC 29609
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 A01
Serious15$2,800$1,120Jan 6, 2004--
010021926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 A03
Serious15$2,000$800Jan 6, 2004--
020011926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01
Other1110$0$0Jan 13, 2004--
Sep 17, 2002Planned (H) · Complete scope, Safety#300271632$3002 viol.

Inspection #300271632

Dates

Opened
Sep 17, 2002
Closing Conference Date
Sep 23, 2002
Closed
Nov 6, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$750
Penalties on Record
$300
Site Address
4212 East North Street, Greenville, SC 29615
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious88$375$150Oct 7, 2002--
010021926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 B02
Serious38$375$150Oct 7, 2002--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.416Electrical - Safety Requirements (Construction)2 citations · $1,920
1926.501Fall Protection - Duty to Have Fall Protection2 citations · $150
1926.1052Stairways (Construction)2 citations · $0

Industry comparison

Violations per inspection
This employer2.3
Industry average1.5
Penalties per inspection
This employer$740
Industry average$1,287

Construction of Buildings, 202,798 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: residential building construction reported 2.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 8.5%; NAICS 2361 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Greenville, SC

All employers in Greenville →