PIONEER ALUMINUM FORGE
$800
penalties
22
viol.
1
insp.

PIONEER ALUMINUM FORGE

1150 GARDEN OF THE GODS ROAD, Colorado Springs, CO 80907

Inspections
1
Jun 1987 to Jun 1987 · 0 safety, 1 health
Violations
22
across 1 inspection
Penalties on record
$800
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 0Other 10

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 3, 1987Complaint (B) · Partial scope, Health#100611177$80022 viol.

Inspection #100611177

Dates

Opened
Jun 3, 1987
Closing Conference Date
Oct 6, 1987
Closed
Mar 4, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8
Related Activity
2 complaints

Violations and Penalties

Total Violations
22
Violation Types
12 serious, 10 other-than-serious
Initial Penalties
$1,800
Penalties on Record
$800
Site Address
1150 Garden Of The Gods Road, Colorado Springs, CO 80907
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)1411P / 3A0mg/m³
Beryllium and Beryllium Compounds (as Be)1311P / 2A0mg/m³
Cadmium Fume (as Cd)1411P / 3A0mg/m³
Chromium, Metal and Insoluble Salts1411P / 3A0 - 0.063mg/m³
Cobalt, Metal, Dust and Fume (as Co)1411P / 3A0mg/m³
Copper Fume (as Cu)1411P / 3A0 - 0.4326mg/m³
Iron Oxide Fume1411P / 3A0 - 0.3808mg/m³
Lead, Inorganic (as Pb)1411P / 3A0 - 2.5016mg/m³
Manganese Fume (as Mn)1411P / 3A0 - 0.0163mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)1411P / 3A0mg/m³
Nickel, Metal and Insoluble compounds (as Ni)1411P / 3A0mg/m³
Particulates not otherwise regulated (Respirable Fraction)1411P / 3A0mg/m³
Vanadium fume (as V2O5)1411P / 3A0 - 0.0322mg/m³
Zinc Oxide Fume1411P / 3A0 - 2.105mg/m³

Violations

Violation list (22 of 22 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 C01
Serious12$300$150Dec 3, 1987--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$360$130Jan 10, 1988--
01003A1910.1025
Lead
OSHA citation code: 19101025 C01
Serious11$360$150Dec 17, 1987--
01003B1910.1025
Lead
OSHA citation code: 19101025 F03 II
Serious11$0$0Dec 16, 1987--
01003C1910.1025
Lead
OSHA citation code: 19101025 F04 I
Serious11$0$0Dec 17, 1987--
01003D1910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Serious11$0$0Dec 17, 1987--
01003E1910.134
Respiratory Protection
OSHA citation code: 19100134 B03
Serious12$0$0Dec 3, 1987--
01003F1910.134
Respiratory Protection
OSHA citation code: 19100134 E05 I
Serious11$0$0Nov 23, 1987--
01004A1910.1025
Lead
OSHA citation code: 19101025 D01 II
Serious19$420$160Jan 10, 1988--
01004B1910.1025
Lead
OSHA citation code: 19101025 D06 III
Serious18$0$0Jan 10, 1988--
010051910.1025
Lead
OSHA citation code: 19101025 G01
Serious11$360$110Jan 10, 1988--
01006B1910.1025
Lead
OSHA citation code: 19101025 J03 IB
Serious29$0$100Dec 20, 1987--
02001A1910.20
OSHA citation code: 19100020 G01
Other18$0$0Dec 3, 1987--
02001B1910.20
OSHA citation code: 19100020 G02
Other18$0$0Nov 21, 1987--
02002A1910.27
OSHA citation code: 19100027 C06
Other12$0$0Dec 3, 1987--
02002B1910.27
OSHA citation code: 19100027 D03
Other12$0$0Dec 3, 1987--
02002C1910.27
OSHA citation code: 19100027 F
Other12$0$0Nov 26, 1987--
020031910.1025
Lead
OSHA citation code: 19101025 G02 VI
Other18$0$0Nov 26, 1987--
020041910.1025
Lead
OSHA citation code: 19101025 H01
Other18$0$0Dec 3, 1987--
020051910.1025
Lead
OSHA citation code: 19101025 I02 II
Other11$0$0Dec 20, 1987--
020061910.1025
Lead
OSHA citation code: 19101025 L01 VD
Other11$0$0Dec 3, 1987--
020071910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Other110$0$0Dec 4, 1987--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.