Skip to content
SafetyRecord logoSafetyRecord
POCAHONTAS ALUMINUM COMPANY, INC.
$50,000
penalties
43
viol.
2
insp.

POCAHONTAS ALUMINUM COMPANY, INC.

2001 INDUSTRIAL DRIVE, Pocahontas, AR 72455NAICS 332321 Metal Window and Door Manufacturing

Inspections
2
Oct 2010 to Nov 2010 · 1 safety, 1 health
Violations
43
across 2 inspections
Penalties on record
$50,000
latest amounts in DOL records
By classification
Serious 32Willful 0Repeat 4Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 15, 2010Referral (C) · Complete scope, Health#315041202$11,00022 viol.

Inspection #315041202

Dates

Opened
Nov 15, 2010
Closing Conference Date
Apr 8, 2011
Contested
May 2, 2011
Final Order
Oct 17, 2011
Closed
Feb 1, 2012

Inspection

Advance Notice
Yes
Owner Type
Private
Union Status
No
Number of Employees
85
Related Activity
1 referral

Violations and Penalties

Total Violations
22
Violation Types
19 serious, 3 other-than-serious
Initial Penalties
$12,320
Penalties on Record
$11,000
Site Address
2001 Industrial Drive, Pocahontas, AR 72455
Industry
332321 Metal Window and Door Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium20mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20mg/m³
Gravimetric DeterminationQC20.1568 - 0.5442mg/m³
Iron Oxide Fume20mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Particulates not otherwise regulated (Total Dust)20.1568 - 0.5442mg/m³
Sample WeightQC20.069 - 0.234mg
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20mg/m³

Violations

Violation list (22 of 22 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious14$5,390$2,750May 4, 2011May 2, 2011Oct 17, 2011
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Serious34$0$0May 4, 2011May 2, 2011Oct 17, 2011
01001C1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I04
Serious14$0$0May 4, 2011May 2, 2011Oct 17, 2011
01001D1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I05
Serious14$0$0May 4, 2011May 2, 2011Oct 17, 2011
01001E1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K03 I
Serious16$0$0May 4, 2011May 2, 2011Oct 17, 2011
01001F1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K03 II
Serious16$0$0May 4, 2011May 2, 2011Oct 17, 2011
01009A1910.1200
Hazard Communication
OSHA citation code: 19101200 H02 III
Serious1-$5,390$2,750Apr 20, 2011May 2, 2011Oct 17, 2011
01009B1910.1200
Hazard Communication
OSHA citation code: 19101200 H03 II
Serious1-$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
01009C1910.1200
Hazard Communication
OSHA citation code: 19101200 H03 IV
Serious1-$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
01010A1910.132
General requirements
OSHA citation code: 19100132 A
Serious2-$0$2,750Apr 20, 2011May 2, 2011Oct 17, 2011
01010B1910.132
General requirements
OSHA citation code: 19100132 D01
Serious1-$0$0Apr 28, 2011May 2, 2011Oct 17, 2011
01010C1910.133
Eye and Face Protection
OSHA citation code: 19100133 A02
Serious2-$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
01010D1910.133
Eye and Face Protection
OSHA citation code: 19100133 A03
Serious2-$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
01010E1910.138
Hand Protection
OSHA citation code: 19100138 A
Serious3-$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
01011A1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 C01 I
Serious1-$0$2,750Apr 20, 2011May 2, 2011Oct 17, 2011
01011B1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 C02 I
Serious1-$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
01011C1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 F02 I
Serious1-$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
01011D1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 G02 VIIK
Serious1-$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
01011E1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 G02 VIIL
Serious1-$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
020011904.29
Forms
OSHA citation code: 19040029 B01
Other4-$770$0Apr 27, 2011May 2, 2011Oct 17, 2011
020021904.31
Covered employees
OSHA citation code: 19040031 A
Other4-$770$0Apr 27, 2011May 2, 2011Oct 17, 2011
020031910.134
Respiratory Protection
OSHA citation code: 19100134 D01 III
Other1-$0$0May 4, 2011May 2, 2011Oct 17, 2011
Oct 29, 2010Planned (H) · Complete scope, Safety#314914458$39,00021 viol.

Inspection #314914458

Dates

Opened
Oct 29, 2010
Closing Conference Date
Apr 8, 2011
Contested
May 2, 2011
Final Order
Oct 17, 2011
Closed
Sep 8, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
85

Violations and Penalties

Total Violations
21
Violation Types
13 serious, 4 repeat, 4 other-than-serious
Initial Penalties
$97,020
Penalties on Record
$39,000
Site Address
2001 Industrial Drive, Pocahontas, AR 72455
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (21 of 21 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 C01
Serious25$5,390$3,000Apr 20, 2011May 2, 2011Oct 17, 2011
010021910.26
OSHA citation code: 19100026 C02 VII
Serious24$5,390$3,000Apr 20, 2011May 2, 2011Oct 17, 2011
010031910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Serious212$5,390$3,000Apr 20, 2011May 2, 2011Oct 17, 2011
010041910.176
Handling Materials - General
OSHA citation code: 19100176 B
Other1-$5,390$3,000Apr 20, 2011May 2, 2011Oct 17, 2011
010051910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 G01
Serious243$5,390$3,000Apr 27, 2011May 2, 2011Oct 17, 2011
010061910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 N01
Other14$5,390$0Apr 20, 2011May 2, 2011Oct 17, 2011
01008A1910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 B02 I
Serious11$5,390$3,000Apr 20, 2011May 2, 2011Oct 17, 2011
01008B1910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 B02 IIIA
Serious11$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
01008C1910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 B02 IVA
Serious11$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
01008D1910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 B02 IVB
Serious11$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
010091910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other116$5,390$0Apr 20, 2011May 2, 2011Oct 17, 2011
01011A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious2218$0$3,000Apr 27, 2011May 2, 2011Oct 17, 2011
01011B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IB
Serious1340$0$0Apr 27, 2011May 2, 2011Oct 17, 2011
020011910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious14$10,780$3,000Apr 20, 2011May 2, 2011Oct 17, 2011
020021910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious13-$10,780$3,000Apr 20, 2011May 2, 2011Oct 17, 2011
020031910.217
Mechanical Power Presses
OSHA citation code: 19100217 D06 I
Repeat1538$10,780$4,500Apr 27, 2011May 2, 2011Oct 17, 2011
020041910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Serious1538$10,780$2,000Apr 27, 2011May 2, 2011Oct 17, 2011
02005A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Repeat438$10,780$5,500Apr 20, 2011May 2, 2011Oct 17, 2011
02005B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Repeat13$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
02005C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Repeat23$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
030011910.252
General requirements
OSHA citation code: 19100252 B02 III
Other15$0$0Apr 20, 2011May 2, 2011Oct 17, 2011
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.95Occupational Noise Exposure6 citations · $2,750
1910.1030Bloodborne Pathogens5 citations · $2,750
1910.217Mechanical Power Presses5 citations · $12,500

Chemical exposure sampling

Samples
32
Substances
16
Inspections
1

Industry comparison

Violations per inspection
This employer21.5
Industry average3.3
Penalties per inspection
This employer$25,000
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,936 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: metal window and door manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.3%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Pocahontas, AR

All employers in Pocahontas →