SAMUELS RECYCLING
1753 BELOIT AVENUE, JANESVILLE, WI 53546 · NAICS 423930 Recyclable Material Merchant Wholesalers
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 10, 2007#308387729Jan 10, 2007Planned (H) · Complete scope, Health#308387729$3,4007 viol.7 violations$3,400 in penalties
Inspection #308387729
Dates
- Opened
- Jan 10, 2007
- Closing Conference Date
- Feb 16, 2007
- Contested
- Mar 23, 2007
- Final Order
- Nov 28, 2007
- Closed
- Dec 26, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 30
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 5 other-than-serious, 2 unclassified
- Initial Penalties
- $8,500
- Penalties on Record
- $3,400
- Site Address
- 1753 Beloit Avenue, Janesville, WI 53546
- Industry
- 423930 Recyclable Material Merchant Wholesalers
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 3 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 3 | 0 | mg/m³ |
| Cadmium | 3 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 3 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 3 | 0 | mg/m³ |
| Copper Fume (as Cu) | 3 | 0 - 0.0310124 | mg/m³ |
| Gravimetric DeterminationQC | 3 | 0.1235 - 1.0919 | mg/m³ |
| Iron Oxide Fume | 3 | 0 - 0.0497522 | mg/m³ |
| Lead, Inorganic (as Pb) | 3 | 0 - 0.011 | mg/m³ |
| Manganese Fume (as Mn) | 3 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 3 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 3 | 0 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 3 | 0.1235 - 1.0919 | mg/m³ |
| Sample WeightQC | 3 | 0.112 - 0.85 | mg |
| Vanadium fume (as V2O5) | 3 | 0 | mg/m³ |
| Zinc Oxide Fume | 3 | 0 | mg/m³ |
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01002 | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B04 III | Other | 1 | 1 | $1,700 | $850 | Mar 8, 2007 | Mar 23, 2007 | Nov 28, 2007 |
| 01003 | 1910.1025 Lead OSHA citation code: 19101025 D02 | Other | 2 | 2 | $1,700 | $850 | Mar 8, 2007 | Mar 23, 2007 | Nov 28, 2007 |
| 01005A | 1910.1025 Lead OSHA citation code: 19101025 H03 | Unclassified | 2 | 2 | $1,700 | $0 | Mar 23, 2007 | Mar 23, 2007 | Nov 28, 2007 |
| 01005B | 1910.1027 Cadmium OSHA citation code: 19101027 K03 | Unclassified | 1 | 2 | $0 | $0 | Mar 23, 2007 | Mar 23, 2007 | Nov 28, 2007 |
| 01006 | 1910.1025 Lead OSHA citation code: 19101025 L01 I | Other | 2 | 2 | $1,700 | $850 | Mar 23, 2007 | Mar 23, 2007 | Nov 28, 2007 |
| 01007 | 1910.1027 Cadmium OSHA citation code: 19101027 M04 I | Other | 2 | 2 | $1,700 | $850 | Mar 23, 2007 | Mar 23, 2007 | Nov 28, 2007 |
| 02001 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 A02 IIIF | Other | 1 | 1 | $0 | $0 | Mar 8, 2007 | Mar 23, 2007 | Nov 28, 2007 |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
Standards cited
Chemical exposure sampling
Industry comparison
Merchant Wholesalers, Durable Goods, 24,701 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: recyclable material merchant wholesalers reported 3.7 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.0%; NAICS 42393 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source