Skip to content
SafetyRecord logoSafetyRecord
SHAW STUCCO
$19,100
penalties
28
viol.
2
insp.

SHAW STUCCO

11215 SOUTH 4460 WEST, SOUTH JORDAN, UT 84095NAICS 238310 Drywall and Insulation Contractors

Inspections
2
Jun 2005 to Jul 2005 · 2 safety, 0 health
Violations
28
across 2 inspections
Penalties on record
$19,100
latest amounts in DOL records
By classification
Serious 24Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 21, 2005Planned (H) · Complete scope, Safety#309162543$10,45013 viol.

Inspection #309162543

Dates

Opened
Jul 21, 2005
Closing Conference Date
Jul 21, 2005
Closed
Sep 30, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
13
Violation Types
11 serious, 2 other-than-serious
Initial Penalties
$10,450
Penalties on Record
$10,450
Site Address
11215s.4355w & 1215s.4460w Lot#1 & #2 Rainey Homes, South Jordan, UT 84095
Industry
238140 Masonry Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (13 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Serious214$4,200$4,200Sep 12, 2005--
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01 I
Serious214$0$0Sep 14, 2005--
01001C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B02
Serious114$0$0Sep 14, 2005--
01001D1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02
Serious114$0$0Sep 14, 2005--
01001E1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C03
Serious114$0$0Sep 14, 2005--
01001F1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious214$0$0Sep 14, 2005--
01001G1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F03
Serious214$0$0Sep 14, 2005--
01001H1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G04 I
Serious214$0$0Sep 14, 2005--
01002A1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious114$4,200$4,200Sep 14, 2005--
01002B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 A02
Serious214$0$0Sep 14, 2005--
010031926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious214$1,200$1,200Sep 14, 2005--
020011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Other114$600$600Sep 14, 2005--
020021904.29
Forms
OSHA citation code: 19040029 A
Other114$250$250Sep 14, 2005--
Jun 15, 2005Planned (H) · Partial scope, Safety#306621525$8,65015 viol.

Inspection #306621525

Dates

Opened
Jun 15, 2005
Closing Conference Date
Jun 15, 2005
Closed
Sep 30, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
15
Violation Types
13 serious, 2 other-than-serious
Initial Penalties
$8,650
Penalties on Record
$8,650
Site Address
11215 South 4460 West, South Jordan, UT 84095
Industry
238310 Drywall and Insulation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (15 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious16$1,200$1,200Jul 5, 2005--
01002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Serious16$3,000$3,000Jul 5, 2005--
01002B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01 I
Serious16$0$0Jul 5, 2005--
01002C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B02
Serious16$0$0Jul 19, 2005--
01002D1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02
Serious16$0$0Jul 5, 2005--
01002E1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C03
Serious16$0$0Jul 5, 2005--
01002F1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious16$0$0Jul 5, 2005--
01002G1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F03
Serious16$0$0Jul 5, 2005--
01002H1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G04 I
Serious16$0$0Jul 5, 2005--
01002I1926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 C04
Serious16$0$0Jul 5, 2005--
01003A1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious16$3,000$3,000Jul 5, 2005--
01003B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 A02
Serious16$0$0Jul 19, 2005--
010041926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious16$1,200$1,200Jul 19, 2005--
020011926.29
Acceptable certifications
OSHA citation code: 19260029 A
Other16$250$250Jul 5, 2005--
020021926.25
Housekeeping
OSHA citation code: 19260025 A
Other16$0$0Jul 5, 2005--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements16 citations · $7,200
1926.503Fall Protection - Training Requirements2 citations · $2,400
1926.100Head Protection (Construction)2 citations · $1,800

Industry comparison

Violations per inspection
This employer14.0
Industry average2.1
Penalties per inspection
This employer$9,550
Industry average$2,542

Specialty Trade Contractors, 558,619 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in SOUTH JORDAN, UT

All employers in SOUTH JORDAN →