Skip to content
SafetyRecord logoSafetyRecord
SYCAMORE HOME IMPROVEMENT, INC.
$5,600
penalties
9
viol.
2
insp.

SYCAMORE HOME IMPROVEMENT, INC.

3432 NEWARK AVE., NW, WASHINGTON, DC 20015NAICS 236115 New Single-Family Housing Construction (except For-Sale Builders)

Inspections
2
Jul 2013 to Jan 2014 · 2 safety, 0 health
Violations
9
across 2 inspections
Penalties on record
$5,600
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 9, 2014Referral (C) · Complete scope, Safety#339547028$3,2003 viol.

Inspection #339547028

Dates

Opened
Jan 9, 2014
Closing Conference Date
Jan 9, 2014
Final Order
May 12, 2014
Closed
Sep 5, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$3,200
Penalties on Record
$3,200
Site Address
3432 Newark St., Nw, Washington, DC 20015
Industry
236115 New Single-Family Housing Construction (except For-Sale Builders)

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.150
Fire Protection (Construction)
OSHA citation code: 19260150 A03
Serious14$1,200$1,200Apr 2, 2014-May 12, 2014
01001B1926.153
Liquefied Petroleum Gas (LP-Gas)
OSHA citation code: 19260153 L
Serious24$0$0Apr 2, 2014-May 12, 2014
010021926.304
Woodworking Tools
OSHA citation code: 19260304 F
Serious12$2,000$2,000Apr 2, 2014-May 12, 2014
Jul 29, 2013Planned (H) · Complete scope, Safety#339428567$2,4006 viol.

Inspection #339428567

Dates

Opened
Jul 29, 2013
Closing Conference Date
Jul 29, 2013
Final Order
Dec 2, 2013
Closed
Dec 5, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$4,800
Penalties on Record
$2,400
Site Address
3432 Newark Ave., Nw, Washington, DC 20015
Industry
236115 New Single-Family Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.100
Head protection
OSHA citation code: 19260100 A
Serious12$1,200$600-Dec 2, 2013
01001B1926.102
Eye and face protection
OSHA citation code: 19260102 A01
Serious12$0$0-Dec 2, 2013
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious23$2,000$1,000Nov 30, 2013-Dec 2, 2013
01003A1926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01 I
Serious14$1,600$800Nov 30, 2013-Dec 2, 2013
01003B1926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01 II
Serious14$0$0Nov 30, 2013-Dec 2, 2013
020011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Other12$0$0Nov 30, 2013-Dec 2, 2013
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.1052Stairways (Construction)2 citations · $800
1926.102Eye and face protection1 citation · $0
1926.150Fire Protection (Construction)1 citation · $1,200

Industry comparison

Violations per inspection
This employer4.5
Industry average1.5
Penalties per inspection
This employer$2,800
Industry average$1,286

Construction of Buildings, 202,676 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: residential building construction reported 2.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 8.5%; NAICS 2361 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in WASHINGTON, DC