Skip to content
SafetyRecord logoSafetyRecord
TIGER STEEL CORPORATION
$2,730
penalties
28
viol.
5
insp.

TIGER STEEL CORPORATION

5757 BIRD CREEK AVE., Catoosa, OK 74015

Inspections
5
Apr 1987 to Nov 1990 · 2 safety, 3 health
Violations
28
across 5 inspections
Penalties on record
$2,730
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 2Other 14

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 7, 1990Follow-Up (F) · Partial scope, Health#107499386$00 viol.

Inspection #107499386

Dates

Opened
Nov 7, 1990
Closing Conference Date
Nov 7, 1990
Closed
Jul 10, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
31

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
5757 Bird Creek Ave, Catoosa, OK 74015
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 12, 1990Follow-Up (F) · Partial scope, Health#106654478$00 viol.

Inspection #106654478

Dates

Opened
Jul 12, 1990
Closing Conference Date
Jul 12, 1990
Closed
Aug 17, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
31

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
5757 Bird Creek Ave, Catoosa, OK 74015
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 1, 1990Planned (H) · Complete scope, Safety#102255254$1,38012 viol.

Inspection #102255254

Dates

Opened
May 1, 1990
Closing Conference Date
May 1, 1990
Closed
Jul 10, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
12
Violation Types
7 serious, 5 other-than-serious
Initial Penalties
$1,380
Penalties on Record
$1,380
Site Address
5757 Bird Creek Ave., Catoosa, OK 74015
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
OSHA citation code: 19100106 G03 IVD
Serious12$60$60Jul 10, 1990--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C06
Serious11$120$120Jul 10, 1990--
010031910.132
General requirements
OSHA citation code: 19100132 A
Serious2020$420$420Jul 10, 1990--
010041910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 L03 II
Serious25$150$150Jul 10, 1990--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious220$300$300Jun 25, 1990--
010061910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C03
Serious520$180$180Jul 10, 1990--
010071910.304
Wiring design and protection
OSHA citation code: 19100304 F05 V
Serious11$150$150Jun 20, 1990--
020011910.106
OSHA citation code: 19100106 G08
Other12$0$0Jul 10, 1990--
020021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Other11$0$0Jul 10, 1990--
020031910.184
Slings
OSHA citation code: 19100184 E01
Other45$0$0Jun 25, 1990--

Showing the 10 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 21, 1990Planned (H) · Complete scope, Health#102418571$1,2608 viol.

Inspection #102418571

Dates

Opened
Mar 21, 1990
Closing Conference Date
Mar 21, 1990
Closed
Jul 10, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
21

Violations and Penalties

Total Violations
8
Violation Types
3 serious, 2 repeat, 3 other-than-serious
Initial Penalties
$1,260
Penalties on Record
$1,260
Site Address
5757 Bird Creek Ave, Catoosa, OK 74015
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Cadmium Fume (as Cd)20mg/m³
Chromium, Metal and Insoluble Salts20 - 0.0036mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20 - 0.0019mg/m³
Iron Oxide Fume20 - 0.066mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20 - 0.0087mg/m³

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 I
Serious12$160$160Jun 5, 1990--
010021910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 A02 IIIG
Serious16$160$160Jun 5, 1990--
010031910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Serious16$160$160Jun 5, 1990--
020011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Repeat120$360$360Jun 7, 1990--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 H
Repeat120$420$420Dec 26, 1990--
030011904.2
OSHA citation code: 19040002 A
Other220$0$0Jun 7, 1990--
030021910.20
OSHA citation code: 19100020 G02
Other120$0$0Jun 5, 1990--
030031910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other44$0$0Jul 5, 1990--

Failure to Abate Penalties4 citations, $3,500 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 4 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001#106654478Aug 16, 1990$700--
02002#107499386Nov 26, 1990$2,100--
03002#106654478Aug 16, 1990$350--
03003#106654478Aug 16, 1990$350--
Apr 24, 1987Planned (H) · Complete scope, Safety#100636505$908 viol.

Inspection #100636505

Dates

Opened
Apr 24, 1987
Closing Conference Date
Apr 24, 1987
Closed
Aug 21, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
8
Violation Types
2 serious, 6 other-than-serious
Initial Penalties
$90
Penalties on Record
$90
Site Address
5757 Bird Creek Ave., Catoosa, OK 74015
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious1-$90$90May 25, 1987--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious14$0$0May 25, 1987--
020011904.2
OSHA citation code: 19040002 A
Other112$0$0May 25, 1987--
020021910.22
OSHA citation code: 19100022 A01
Other1012$0$0May 25, 1987--
020031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Other6-$0$0May 25, 1987--
020041910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G02 III
Other64$0$0May 25, 1987--
020051910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other1-$0$0Jun 29, 1987--
020061910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other1-$0$0Jun 29, 1987--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication4 citations · $780
1910.305Wiring methods, components, and equipment for general use3 citations · $320
1910.1062 citations · $60

Chemical exposure sampling

Samples
25
Substances
13
Inspections
1

Other inspected employers in Catoosa, OK