TRACEY MECHANICAL, INC.
CITIZENS BANK BALLPARK, PHILADELPHIA, PA 19148 · NAICS 238220 Plumbing, Heating, and Air-Conditioning Contractors
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jul 14, 1982#12634390Jul 14, 1982Unprogrammed Related (G) · Complete scope, Safety#12634390$4806 viol.6 violations$480 in penalties
Inspection #12634390
Dates
- Opened
- Jul 14, 1982
- Closing Conference Date
- Aug 5, 1982
- Closed
- Jun 28, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 10
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 3 serious, 3 other-than-serious
- Initial Penalties
- $480
- Penalties on Record
- $480
- Site Address
- 210 West Rittenhouse Square, Philadelphia, PA 19103
- Industry
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1926.400 Introduction (Electrical - Construction) OSHA citation code: 19260400 H01 | Serious | 1 | - | $480 | $480 | Aug 27, 1982 | - | - |
| 01001B | 1926.401 OSHA citation code: 19260401 C | Serious | 1 | - | $0 | $0 | Aug 5, 1982 | - | - |
| 01001C | 1926.402 Applicability (Electrical - Construction) OSHA citation code: 19260402 A05 | Serious | 1 | - | $0 | $0 | Aug 5, 1982 | - | - |
| 02001 | 1926.25 Housekeeping OSHA citation code: 19260025 A | Other | 1 | - | $0 | $0 | Aug 5, 1982 | - | - |
| 02002 | 1926.350 Gas Welding and Cutting OSHA citation code: 19260350 A01 | Other | 1 | - | $0 | $0 | Aug 5, 1982 | - | - |
| 02003 | 1926.350 Gas Welding and Cutting OSHA citation code: 19260350 A09 | Other | 1 | - | $0 | $0 | Aug 5, 1982 | - | - |
Oct 16, 1981#12726899Oct 16, 1981Unprogrammed Related (G) · Complete scope, Safety#12726899$7804 viol.4 violations$780 in penalties
Inspection #12726899
Dates
- Opened
- Oct 16, 1981
- Closing Conference Date
- Nov 13, 1981
- Closed
- Mar 5, 1982
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 18
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $780
- Penalties on Record
- $780
- Site Address
- 210 W Rittenhouse Square, Philadelphia, PA 19103
- Industry
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.25 Housekeeping OSHA citation code: 19260025 A | Serious | 1 | - | $420 | $420 | Dec 14, 1981 | - | - |
| 01002A | 1926.350 Gas Welding and Cutting OSHA citation code: 19260350 A01 | Serious | 2 | - | $360 | $360 | Dec 14, 1981 | - | - |
| 01002B | 1926.350 Gas Welding and Cutting OSHA citation code: 19260350 A09 | Serious | 1 | - | $0 | $0 | Dec 14, 1981 | - | - |
| 01002C | 1926.350 Gas Welding and Cutting OSHA citation code: 19260350 J | Serious | 2 | - | $0 | $0 | Dec 14, 1981 | - | - |
Feb 14, 1978#12756961Feb 14, 1978Complaint (B) · Complete scope, Safety#12756961$04 viol.4 violations$0 in penalties
Inspection #12756961
Dates
- Opened
- Feb 14, 1978
- Closing Conference Date
- Mar 6, 1978
- Closed
- May 5, 1978
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 10
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 24 Chestnut St, Philadelphia, PA 19103
- Industry
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.51 Sanitation (Construction) OSHA citation code: 19260051 B01 | Other | 1 | - | $0 | $0 | Apr 12, 1978 | - | - |
| 01002 | 1926.51 Sanitation (Construction) OSHA citation code: 19260051 C01 | Other | 1 | - | $0 | $0 | Apr 12, 1978 | - | - |
| 01003 | 1926.51 Sanitation (Construction) OSHA citation code: 19260051 F | Other | 1 | - | $0 | $0 | Apr 12, 1978 | - | - |
| 01004 | 1926.400 Introduction (Electrical - Construction) OSHA citation code: 19260400 H01 | Other | 1 | - | $0 | $0 | Apr 19, 1978 | - | - |
May 31, 1974#12674636May 31, 1974Planned (H) · Complete scope, Safety#12674636$1,6004 viol.4 violations$1,600 in penalties
Inspection #12674636
Dates
- Opened
- May 31, 1974
- Closing Conference Date
- May 31, 1974
- Contested
- Jun 15, 1974
- Closed
- Jul 11, 1974
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Not displayed
- Number of Employees
- 4
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 1 repeat, 3 other-than-serious
- Initial Penalties
- $1,600
- Penalties on Record
- $1,600
- Site Address
- 34th And Civic Center Road, Philadelphia, PA 19104
- Industry
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.401 OSHA citation code: 19260401 A01 | Other | 1 | - | $0 | $0 | Jun 11, 1974 | - | - |
| 01002 | 1926.500 Fall Protection - Scope, Application, and Definitions OSHA citation code: 19260500 E01 | Other | 1 | - | $0 | $0 | Jun 11, 1974 | Jun 15, 1974 | - |
| 01003 | 1926.150 Fire Protection (Construction) OSHA citation code: 19260150 C01 I | Other | 20 | - | $0 | $0 | Jun 11, 1974 | Jun 15, 1974 | - |
| 02001 | 1926.500 Fall Protection - Scope, Application, and Definitions OSHA citation code: 19260500 B01 | Repeat | 8 | - | $1,600 | $1,600 | Jun 11, 1974 | Jun 15, 1974 | - |
Dec 19, 1973#12673570Dec 19, 1973Planned (H) · Complete scope, Safety#12673570$255 viol.5 violations$25 in penalties
Inspection #12673570
Dates
- Opened
- Dec 19, 1973
- Closing Conference Date
- Dec 19, 1973
- Closed
- Mar 10, 1984
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Not displayed
- Number of Employees
- 8
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 other-than-serious
- Initial Penalties
- $25
- Penalties on Record
- $25
- Site Address
- 34th And Civic Center Road, Philadelphia, PA 19104
- Industry
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.500 Fall Protection - Scope, Application, and Definitions OSHA citation code: 19260500 B01 | Other | 2 | - | $0 | $0 | Dec 21, 1973 | - | - |
| 01002 | 1926.25 Housekeeping OSHA citation code: 19260025 A | Other | 2 | - | $25 | $25 | Dec 21, 1973 | - | - |
| 01003 | 1926.402 Applicability (Electrical - Construction) OSHA citation code: 19260402 A08 | Other | 3 | - | $0 | $0 | Dec 21, 1973 | - | - |
| 01004 | 1926.500 Fall Protection - Scope, Application, and Definitions OSHA citation code: 19260500 D01 | Other | 1 | - | $0 | $0 | Dec 21, 1973 | - | - |
| 01005 | 1926.500 Fall Protection - Scope, Application, and Definitions OSHA citation code: 19260500 B08 | Other | 1 | - | $0 | $0 | Dec 21, 1973 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
15 inspections, 1973 to 2024. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Specialty Trade Contractors, 558,619 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: plumbing, heating, and air-conditioning contractors reported 3.0 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.2%; NAICS 23822 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source