Skip to content
SafetyRecord logoSafetyRecord
HAGERMAN CONSTRUCTION CORP
$24,129
penalties
75
viol.
42
insp.

HAGERMAN CONSTRUCTION CORP

(MEIJERS STORE)5909 ILLINOIS RD, FORT WAYNE, IN 46804NAICS 238110 Poured Concrete Foundation and Structure Contractors

Inspections
42
Aug 1976 to Jul 2015 · 41 safety, 1 health
Violations
75
across 42 inspections
Penalties on record
$24,129
latest amounts in DOL records
By classification
Serious 32Willful 0Repeat 7Other 36

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 29, 2004Planned (H) · Complete scope, Safety#127389872$00 viol.

Inspection #127389872

Dates

Opened
Jul 29, 2004
Closing Conference Date
Aug 18, 2004
Closed
Oct 21, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
19

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4027 Hathaway Road, Fort Wayne, IN 46818
Industry
238110 Poured Concrete Foundation and Structure Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 27, 2004Planned (H) · No Inspection scope, Safety#127389799$00 viol.

Inspection #127389799

Dates

Opened
Jul 27, 2004
Closing Conference Date
Jul 28, 2004
Closed
Oct 1, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
East Washington Blvd., Fort Wayne, IN 46803
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 7, 2001Planned (H) · Complete scope, Safety#300723236$00 viol.

Inspection #300723236

Dates

Opened
Aug 7, 2001
Closing Conference Date
Aug 9, 2001
Closed
Dec 10, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
15

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Dana Eng. Bldg., Fort Wayne, IN 46803
Industry
238110 Poured Concrete Foundation and Structure Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 6, 1998Planned (H) · Complete scope, Safety#125407692$00 viol.

Inspection #125407692

Dates

Opened
May 6, 1998
Closing Conference Date
May 12, 1998
Closed
Aug 21, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
15

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
(hickory Ctr. Elem.)3606 Baird Rd., Fort Wayne, IN 46818
Industry
238110 Poured Concrete Foundation and Structure Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 22, 1998Planned (H) · Complete scope, Safety#125407593$00 viol.

Inspection #125407593

Dates

Opened
Apr 22, 1998
Closing Conference Date
Apr 23, 1998
Closed
May 8, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
25

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
(parking Garage) Iu/Pu Campus, Fort Wayne, IN 46805
Industry
238110 Poured Concrete Foundation and Structure Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 12, 1997Referral (C) · Partial scope, Health#124033507$1,3753 viol.

Inspection #124033507

Dates

Opened
May 12, 1997
Closing Conference Date
Aug 1, 1997
Closed
Sep 19, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
60
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$2,750
Penalties on Record
$1,375
Site Address
(purdue Science Building) West Campus Drive, Fort Wayne, IN 46805
Industry
238110 Poured Concrete Foundation and Structure Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC14.5224mg/m³
Sample WeightQC20 - 3.731mg
Silica, Crystalline Quartz (Respirable Fraction)11.1%

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.55
Gases, Vapors, Fumes, Dusts, and Mists
OSHA citation code: 19260055 A
Serious11$2,750$1,375Nov 27, 1997--
01001B1926.55
Gases, Vapors, Fumes, Dusts, and Mists
OSHA citation code: 19260055 B
Serious11$0$0Sep 28, 1997--
01001C1926.103
Respiratory Protection (Construction)
OSHA citation code: 19260103 A01
Serious11$0$0Sep 28, 1997--
Mar 3, 1997Planned (H) · Complete scope, Safety#125332890$00 viol.

Inspection #125332890

Dates

Opened
Mar 3, 1997
Closing Conference Date
Mar 13, 1997
Closed
Apr 8, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
60

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
(science Building) West Campus Drive, Fort Wayne, IN 46805
Industry
238110 Poured Concrete Foundation and Structure Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 11, 1996Planned (H) · Complete scope, Safety#123989378$4001 viol.

Inspection #123989378

Dates

Opened
Jul 11, 1996
Closing Conference Date
Jul 18, 1996
Closed
Sep 18, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
60

Violations and Penalties

Total Violations
1
Violation Types
1 repeat
Initial Penalties
$800
Penalties on Record
$400
Site Address
(science Bldg.) 2100 E. Coliseum Blvd., Fort Wayne, IN 46805
Industry
238110 Poured Concrete Foundation and Structure Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Repeat16$800$400Aug 28, 1996--
Mar 4, 1996Planned (H) · Complete scope, Safety#123982050$4,0002 viol.

Inspection #123982050

Dates

Opened
Mar 4, 1996
Closing Conference Date
Mar 7, 1996
Contested
May 17, 1996
Final Order
Aug 20, 1996
Closed
Oct 7, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
30

Violations and Penalties

Total Violations
2
Violation Types
2 repeat
Initial Penalties
$22,500
Penalties on Record
$4,000
Site Address
(plaza Parking Garage) 1 East Main Street, Fort Wayne, IN 46801
Industry
238110 Poured Concrete Foundation and Structure Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.251
Rigging Equipment for Material Handling
OSHA citation code: 19260251 E08 III
Repeat17$7,500$2,000Apr 22, 1996May 17, 1996Aug 20, 1996
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Repeat27$15,000$2,000Apr 22, 1996May 17, 1996Aug 20, 1996
Dec 6, 1995Planned (H) · Complete scope, Safety#124016916$00 viol.

Inspection #124016916

Dates

Opened
Dec 6, 1995
Closing Conference Date
Dec 12, 1995
Closed
Jan 4, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
(south Side High School) 3601 South Calhoun St., Fort Wayne, IN 46807
Industry
238110 Poured Concrete Foundation and Structure Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 11 to 20 of 42, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.404Electrical - Wiring Design and Protection (Construction)11 citations · $4,886
1926.59Hazard Communication6 citations · $2,600
1926.451Scaffolding - General Requirements6 citations · $600

Chemical exposure sampling

Samples
4
Substances
3
Inspections
1

Industry comparison

Violations per inspection
This employer1.8
Industry average2.1
Penalties per inspection
This employer$575
Industry average$2,542

Specialty Trade Contractors, 558,619 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in FORT WAYNE, IN

All employers in FORT WAYNE →