Skip to content
SafetyRecord logoSafetyRecord
P & C METAL POLISHING, INC.
$3,725
penalties
10
viol.
5
insp.

P & C METAL POLISHING, INC.

340 GLENDALE-MILFORD ROAD, CINCINNATI, OH 45215NAICS 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Inspections
5
Jan 1976 to Apr 2015 · 4 safety, 1 health
Violations
10
across 5 inspections
Penalties on record
$3,725
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 1Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 10, 2015Complaint (B) · Partial scope, Safety#340551548$3,7006 viol.

Inspection #340551548

Dates

Opened
Apr 10, 2015
Closing Conference Date
Apr 13, 2015
Final Order
Oct 7, 2015
Closed
Aug 3, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8
Related Activity
1 complaint

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$11,880
Penalties on Record
$3,700
Site Address
340 Glendale-Milford Rd., Cincinnati, OH 45215
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious13$2,520$1,000Oct 21, 2015-Oct 7, 2015
01002A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L01 I
Serious12$2,520$1,000Oct 21, 2015-Oct 7, 2015
01002B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q07
Serious12$2,520$0Oct 21, 2015-Oct 7, 2015
01004A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious33$2,520$1,000Oct 21, 2015-Oct 7, 2015
01004B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious33$0$0Oct 21, 2015-Oct 7, 2015
010051910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Other13$1,800$700Oct 21, 2015-Oct 7, 2015
Jan 20, 2011Planned (H) · Partial scope, Health#315273490$02 viol.

Inspection #315273490

Dates

Opened
Jan 20, 2011
Closing Conference Date
Feb 4, 2011
Closed
Mar 28, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
340 Glendale Milford Road, Cincinnati, OH 45215
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Chromic Acid and Chromates (as CrO3)40mg/m³
Chromium (VI) - TWA40mg/m³

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.133
Eye and Face Protection
OSHA citation code: 19100133 A03
Other12$0$0Feb 17, 2011--
010021910.134
Respiratory Protection
OSHA citation code: 19100134 K06
Other12$0$0Feb 11, 2011--
Dec 14, 1998Referral (C) · Partial scope, Safety#121984827$00 viol.

Inspection #121984827

Dates

Opened
Dec 14, 1998
Closing Conference Date
Dec 14, 1998
Closed
Dec 14, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
340 Glendale-Milford Rd., Cincinnati, OH 45215
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Mar 23, 1976Follow-Up (F) · Complete scope, Safety#14544894$00 viol.

Inspection #14544894

Dates

Opened
Mar 23, 1976
Closing Conference Date
Mar 23, 1976
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
10

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
340 Glendale-Milford Road, Cincinnati, OH 45215
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 16, 1976Follow-Up (F) · Complete scope, Safety#14544597$252 viol.

Inspection #14544597

Dates

Opened
Jan 16, 1976
Closing Conference Date
Jan 16, 1976
Closed
Mar 23, 1976

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
9

Violations and Penalties

Total Violations
2
Violation Types
1 repeat, 1 other-than-serious
Initial Penalties
$25
Penalties on Record
$25
Site Address
340 Glendale Milford Road, Cincinnati, OH 45215
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Other2-$0$0Mar 8, 1976--
020011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Repeat2-$25$25Jan 23, 1976--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus3 citations · $1,025
1910.178Powered Industrial Trucks2 citations · $1,000
1910.147Control of Hazardous Energy (Lockout/Tagout)1 citation · $1,000

Chemical exposure sampling

Samples
8
Substances
2
Inspections
1

Industry comparison

Violations per inspection
This employer2.0
Industry average3.3
Penalties per inspection
This employer$745
Industry average$2,308

Fabricated Metal Product Manufacturing, 47,182 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: electroplating, plating, polishing, anodizing, and coloring reported 4.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.2%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in CINCINNATI, OH

All employers in CINCINNATI →