Skip to content
SafetyRecord logoSafetyRecord
LSO CONSTRUCTION
$8,488
penalties
18
viol.
3
insp.

LSO CONSTRUCTION

PENN'S POINTE, PHILADELPHIA, PA 19147NAICS 238310 Drywall and Insulation Contractors

Inspections
3
Jan 2006 to Aug 2008 · 3 safety, 0 health
Violations
18
across 3 inspections
Penalties on record
$8,488
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 7Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 5, 2008Referral (C) · Partial scope, Safety#310722384$5,00010 viol.

Inspection #310722384

Dates

Opened
Aug 5, 2008
Closing Conference Date
Aug 5, 2008
Closed
Feb 28, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5
Related Activity
1 referral

Violations and Penalties

Total Violations
10
Violation Types
2 serious, 5 repeat, 3 other-than-serious
Initial Penalties
$10,000
Penalties on Record
$5,000
Site Address
1300 South 2nd Street, Philadelphia, PA 19147
Industry
238310 Drywall and Insulation Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C01
Serious13$1,000$1,000Sep 29, 2008--
01001B1926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious12$0$0Sep 29, 2008--
02001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 VII
Repeat13$5,000$2,000Sep 29, 2008--
02001B1926.454
Scaffolding - Training
OSHA citation code: 19260454 A
Repeat13$0$0Oct 8, 2008--
02002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Repeat13$2,000$1,000Sep 29, 2008--
02002B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Repeat13$0$0Oct 8, 2008--
020031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Repeat13$2,000$1,000Sep 29, 2008--
030011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other12$0$0Oct 8, 2008--
030021910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Other12$0$0Sep 29, 2008--
030031910.1200
Hazard Communication
OSHA citation code: 19101200 H01 I
Other12$0$0Oct 8, 2008--
Jul 26, 2006Referral (C) · Partial scope, Safety#308994003$3,0003 viol.

Inspection #308994003

Dates

Opened
Jul 26, 2006
Closing Conference Date
Jul 26, 2006
Closed
Dec 27, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 repeat
Initial Penalties
$3,000
Penalties on Record
$3,000
Site Address
Penn's Pointe, Philadelphia, PA 19147
Industry
238310 Drywall and Insulation Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Serious14$1,000$1,000Aug 21, 2006--
02001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 VII
Repeat14$2,000$2,000Aug 12, 2006--
02001B1926.454
Scaffolding - Training
OSHA citation code: 19260454 A
Repeat14$0$0Aug 21, 2006--
Jan 4, 2006Complaint (B) · Partial scope, Safety#308990621$4885 viol.

Inspection #308990621

Dates

Opened
Jan 4, 2006
Closing Conference Date
Jan 6, 2006
Closed
Feb 6, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3
Related Activity
1 complaint

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$750
Penalties on Record
$488
Site Address
909 North 2nd Street, Philadelphia, PA 19106
Industry
238140 Masonry Contractors

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Serious11$750$488Feb 3, 2006--
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious11$0$0Feb 3, 2006--
01001C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 V
Serious11$0$0Feb 3, 2006--
01001D1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 VII
Serious11$0$0Feb 3, 2006--
01001E1926.454
Scaffolding - Training
OSHA citation code: 19260454 A
Serious11$0$0Feb 28, 2006--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements11 citations · $8,488
1910.1200Hazard Communication3 citations · $0
1926.454Scaffolding - Training3 citations · $0

Industry comparison

Violations per inspection
This employer6.0
Industry average2.1
Penalties per inspection
This employer$2,829
Industry average$2,540

Specialty Trade Contractors, 559,279 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in PHILADELPHIA, PA