Skip to content
SafetyRecord logoSafetyRecord
HAUGHEY STUCCO INC.
$10,100
penalties
17
viol.
2
insp.

HAUGHEY STUCCO INC.

N. 18TH STREET & W. NORRIS STREET, PHILADELPHIA, PA 19121NAICS 238140 Masonry Contractors

Inspections
2
Sep 2008 to Aug 2009 · 2 safety, 0 health
Violations
17
across 2 inspections
Penalties on record
$10,100
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 2Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 25, 2009Programmed Related (I) · Partial scope, Safety#312491921$8,60013 viol.

Inspection #312491921

Dates

Opened
Aug 25, 2009
Closing Conference Date
Aug 25, 2009
Closed
Jun 4, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
13
Violation Types
11 serious, 2 repeat
Initial Penalties
$8,600
Penalties on Record
$8,600
Site Address
N. 18th Street & W. Norris Street, Philadelphia, PA 19121
Industry
238140 Masonry Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (13 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B02
Serious13$1,000$1,000Oct 9, 2009--
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B07
Serious13$0$0Oct 9, 2009--
01001C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 V
Serious13$0$0Oct 9, 2009--
01002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 VII
Serious13$2,000$2,000Oct 9, 2009--
01002B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Serious13$0$0Oct 9, 2009--
01002C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious13$0$0Oct 9, 2009--
01003A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 H02
Serious13$1,000$1,000Oct 9, 2009--
01003B1926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious13$0$0Oct 9, 2009--
01004A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious13$600$600Oct 18, 2009--
01004B1910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Serious13$0$0Oct 9, 2009--
01004C1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Serious13$0$0Oct 18, 2009--
020011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Repeat13$2,000$2,000Oct 9, 2009--
020021926.454
Scaffolding - Training
OSHA citation code: 19260454 A
Repeat13$2,000$2,000Oct 18, 2009--
Sep 19, 2008Referral (C) · Partial scope, Safety#312485501$1,5004 viol.

Inspection #312485501

Dates

Opened
Sep 19, 2008
Closing Conference Date
Sep 19, 2008
Closed
Apr 11, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$1,500
Penalties on Record
$1,500
Site Address
157 Laurel Street, Philadelphia, PA 19123
Industry
238140 Masonry Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G04 I
Serious12$1,500$1,500Jan 17, 2009--
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C01 II
Serious12$0$0Jan 17, 2009--
01001C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Serious12$0$0Jan 17, 2009--
01001D1926.454
Scaffolding - Training
OSHA citation code: 19260454 A
Serious12$0$0Jan 17, 2009--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements11 citations · $7,500
1910.1200Hazard Communication3 citations · $600
1926.454Scaffolding - Training2 citations · $2,000

Industry comparison

Violations per inspection
This employer8.5
Industry average2.1
Penalties per inspection
This employer$5,050
Industry average$2,540

Specialty Trade Contractors, 559,382 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: masonry contractors reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 15.2%; NAICS 23814 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in PHILADELPHIA, PA

All employers in PHILADELPHIA →