Skip to content
SafetyRecord logoSafetyRecord
P 2 CONTRACTING LLC
$10,640
penalties
16
viol.
2
insp.

P 2 CONTRACTING LLC

955 LIBERTY AVENUE, PITTSBURGH, PA 15237NAICS 236220 Commercial and Institutional Building Construction

Inspections
2
Mar 2015 to Jul 2018 · 2 safety, 0 health
Violations
16
across 2 inspections
Penalties on record
$10,640
latest amounts in DOL records
By classification
Serious 14Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 11, 2018Planned (H) · Partial scope, Safety#343296067$7,70013 viol.

Inspection #343296067

Dates

Opened
Jul 11, 2018
Closing Conference Date
Aug 3, 2018
Final Order
Aug 30, 2018
Closed
Sep 11, 2018

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30

Violations and Penalties

Total Violations
13
Violation Types
12 serious, 1 other-than-serious
Initial Penalties
$14,227
Penalties on Record
$7,700
Site Address
955 Liberty Avenue, Pittsburgh, PA 15222
Industry
236118 Residential Remodelers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (13 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 B02
Serious12$4,268$2,300Sep 10, 2018-Aug 30, 2018
01001B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 II B
Serious11$0$0-Aug 30, 2018
01001C1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 II E
Serious14$0$0Sep 10, 2018-Aug 30, 2018
01001D1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 II I
Serious11$0$0-Aug 30, 2018
01001E1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B02
Serious12$0$0-Aug 30, 2018
01001F1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Serious11$0$0-Aug 30, 2018
01002A1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious14$5,691$3,100-Aug 30, 2018
01002B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 B01
Serious14$0$0-Aug 30, 2018
01002C1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B04 II
Serious11$0$0-Aug 30, 2018
01002D1926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious11$0$0Aug 15, 2018-Aug 30, 2018
01003A1926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01 I
Serious11$4,268$2,300Aug 15, 2018-Aug 30, 2018
01003B1926.1052
Stairways (Construction)
OSHA citation code: 19261052 C08
Serious11$0$0-Aug 30, 2018
020011926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Other17$0$0Aug 21, 2018-Aug 30, 2018
Mar 10, 2015Programmed Related (I) · Complete scope, Safety#340452846$2,9403 viol.

Inspection #340452846

Dates

Opened
Mar 10, 2015
Closing Conference Date
Mar 25, 2015
Final Order
Apr 15, 2015
Closed
Apr 15, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
26

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$4,900
Penalties on Record
$2,940
Site Address
7401 Mcknight Road, Pittsburgh, PA 15237
Industry
236220 Commercial and Institutional Building Construction

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.453
Aerial Lifts
OSHA citation code: 19260453 B02 IV
Serious12$4,900$2,940-Apr 15, 2015
01001B1926.453
Aerial Lifts
OSHA citation code: 19260453 B02 V
Serious12$0$0-Apr 15, 2015
020011926.102
Eye and Face Protection (Construction)
OSHA citation code: 19260102 A01
Other11$0$0Apr 2, 2015-Apr 15, 2015
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.405Electrical - Wiring Methods (Construction)5 citations · $0
1926.1052Stairways (Construction)2 citations · $2,300
1926.453Aerial Lifts2 citations · $2,940

Industry comparison

Violations per inspection
This employer8.0
Industry average1.5
Penalties per inspection
This employer$5,320
Industry average$1,290

Construction of Buildings, 209,213 employers with OSHA inspections. Arithmetic from DOL records.