Skip to content
SafetyRecord logoSafetyRecord
GRISTMILL BUILDERS
$8,359
penalties
13
viol.
4
insp.

GRISTMILL BUILDERS

RTE 100, STOWE, VT 05672NAICS 236118 Residential Remodelers

Inspections
4
Oct 2001 to Apr 2026 · 4 safety, 0 health
Violations
13
across 4 inspections
Penalties on record
$8,359
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 1Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 1, 2026Referral (C) · Partial scope, Safety#348847773$2,1281 viol.

Inspection #348847773

Dates

Opened
Apr 1, 2026
Closing Conference Date
Apr 1, 2026
Final Order
May 29, 2026
Closed
Jun 3, 2026

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$2,837
Penalties on Record
$2,128
Site Address
Salvas Ln Lot 7, Stowe, VT 05672
Industry
236115 New Single-Family Housing Construction (except For-Sale Builders)

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L04 III
Serious15$2,837$2,128-May 29, 2026
Aug 9, 2024Planned (H) · Partial scope, Safety#347676264$4,1814 viol.

Inspection #347676264

Dates

Opened
Aug 9, 2024
Closing Conference Date
Aug 9, 2024
Final Order
Sep 24, 2024
Closed
Sep 26, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 repeat
Initial Penalties
$6,971
Penalties on Record
$4,181
Site Address
61 Salvas Lane, Stowe, VT 05672
Industry
236115 New Single-Family Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 H01 III
Serious14$2,764$1,658Sep 6, 2024-Sep 24, 2024
01001B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 K03
Serious13$0$0-Sep 24, 2024
010021926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 B01
Serious14$2,764$1,658Sep 6, 2024-Sep 24, 2024
020011904.29
Forms
OSHA citation code: 19040029 A
Repeat125$1,443$865Sep 20, 2024-Sep 24, 2024
Apr 18, 2007Referral (C) · Partial scope, Safety#308610716$1,4003 viol.

Inspection #308610716

Dates

Opened
Apr 18, 2007
Closing Conference Date
Apr 18, 2007
Closed
Jul 13, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
28
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$2,337
Penalties on Record
$1,400
Site Address
Rte 100, Stowe, VT 05672
Industry
236118 Residential Remodelers

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.150
Fire Protection (Construction)
OSHA citation code: 19260150 A04
Serious14$637$350Jun 12, 2007--
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious14$850$600Jun 12, 2007--
010031926.602
Material Handling Equipment
OSHA citation code: 19260602 C01 II
Serious14$850$450Jun 12, 2007--
Oct 2, 2001Planned (H) · Complete scope, Safety#303454649$6505 viol.

Inspection #303454649

Dates

Opened
Oct 2, 2001
Closing Conference Date
Oct 2, 2001
Closed
Dec 20, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
5
Violation Types
2 serious, 3 other-than-serious
Initial Penalties
$1,350
Penalties on Record
$650
Site Address
Main Street, Stowe, VT 05672
Industry
236118 Residential Remodelers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIE
Other53$450$0Oct 15, 2001--
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 I03
Serious13$450$325Oct 15, 2001--
010031926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious13$450$325Oct 15, 2001--
020011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Other33$0$0Oct 15, 2001--
020021926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 B02
Other13$0$0Oct 15, 2001--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.502Fall Protection Systems Criteria and Practices2 citations · $1,658
1926.405Electrical - Wiring Methods (Construction)2 citations · $325
1926.501Fall Protection - Duty to Have Fall Protection2 citations · $925

Industry comparison

Violations per inspection
This employer3.3
Industry average1.5
Penalties per inspection
This employer$2,090
Industry average$1,290

Construction of Buildings, 209,256 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in STOWE, VT

All employers in STOWE →