Skip to content
SafetyRecord logoSafetyRecord
DELMA CORPORATION DBA DAYTON MANUFACTURING COMPANY
$18,000
penalties
28
viol.
1
insp.

DELMA CORPORATION DBA DAYTON MANUFACTURING COMPANY

3327 ELKTON AVENUE, Dayton, OH 45403NAICS 332322 Sheet Metal Work Manufacturing

Inspections
1
Jan 2009 to Jan 2009 · 0 safety, 1 health
Violations
28
across 1 inspection
Penalties on record
$18,000
latest amounts in DOL records
By classification
Serious 24Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 22, 2009Planned (H) · Complete scope, Health#312869829$18,00028 viol.

Inspection #312869829

Dates

Opened
Jan 22, 2009
Closing Conference Date
Feb 10, 2009
Closed
Jul 27, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
28
Violation Types
24 serious, 4 other-than-serious
Initial Penalties
$36,500
Penalties on Record
$18,000
Site Address
3327 Elkton Avenue, Dayton, OH 45403
Industry
332322 Sheet Metal Work Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling17 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)10mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Cadmium10mg/m³
Chromic Acid and Chromates (as CrO3)20 - 0.054699mg/m³
Chromium, Metal and Insoluble Salts10mg/m³
Chromium (VI) - TWA20 - 0.028445mg/m³
Cobalt, Metal, Dust and Fume (as Co)10mg/m³
Copper Fume (as Cu)10mg/m³
Iron Oxide Fume10.7349785mg/m³
Lead, Inorganic (as Pb)10mg/m³
Manganese Fume (as Mn)10.0714154mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)10mg/m³
Nickel, Metal and Insoluble compounds (as Ni)10mg/m³
Toluene-2,4-Diisocyanate (TDI)30 - 0.007995mg/m³
Toluene-2,6-Diisocyanate30 - 0.012164mg/m³
Vanadium fume (as V2O5)10mg/m³
Zinc Oxide Fume10mg/m³

Violations

Violation list (28 of 28 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.22
OSHA citation code: 19100022 B01
Serious250$1,250$1,000Mar 12, 2009--
01001B1910.37
OSHA citation code: 19100037 A03
Serious150$0$0Mar 12, 2009--
010021910.23
OSHA citation code: 19100023 C01
Serious24$1,250$1,000Apr 6, 2009--
010031910.23
OSHA citation code: 19100023 D01
Serious110$1,250$1,000Apr 6, 2009--
01004A1910.36
OSHA citation code: 19100036 D02
Serious310$1,250$1,000Apr 6, 2009--
01004B1910.36
OSHA citation code: 19100036 E02
Serious250$0$0Apr 6, 2009--
010051910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious18$2,500$2,000May 29, 2009--
010061910.106
OSHA citation code: 19100106 E02 IVD
Serious32$1,250$1,000Apr 6, 2009--
010071910.106
OSHA citation code: 19100106 E06 II
Serious32$1,250$1,000Apr 6, 2009--
010081910.106
OSHA citation code: 19100106 E09 III
Other12$1,250$0Apr 6, 2009--
010091910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Serious12$1,250$1,000May 29, 2009--
01010A1910.132
General requirements
OSHA citation code: 19100132 D01
Serious150$1,250$500Apr 6, 2009--
01010B1910.132
General requirements
OSHA citation code: 19100132 D02
Serious150$0$0Apr 6, 2009--
010111910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious350$2,500$500Apr 6, 2009--
010121910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious12$2,500$1,000Apr 6, 2009--
010131910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious23$1,250$1,000Apr 6, 2009--
010141910.176
Handling Materials - General
OSHA citation code: 19100176 B
Serious135$1,250$1,000Mar 12, 2009--
01015A1910.1026
Chromium (VI)
OSHA citation code: 19101026 C
Serious12$2,500$300Apr 6, 2009--
01015B1910.1026
Chromium (VI)
OSHA citation code: 19101026 G02
Serious12$0$0Apr 6, 2009--
010161910.1026
Chromium (VI)
OSHA citation code: 19101026 D01
Serious14$2,500$300Apr 6, 2009--
010171910.1026
Chromium (VI)
OSHA citation code: 19101026 I01
Serious12$1,250$400Apr 6, 2009--
010181910.1026
Chromium (VI)
OSHA citation code: 19101026 L02
Serious12$2,500$1,000Apr 6, 2009--
01019A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious150$2,500$1,000Apr 6, 2009--
01019B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious450$0$0Mar 12, 2009--
010201910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Serious150$2,500$1,000Apr 6, 2009--
020011910.252
General requirements
OSHA citation code: 19100252 B02 III
Other15$0$0Apr 6, 2009--
030021904.29
Forms
OSHA citation code: 19040029 B01
Other150$1,500$1,000Apr 6, 2009--
030031904.32
Annual Summary
OSHA citation code: 19040032 B02
Other150$0$0Apr 6, 2009--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1026Chromium (VI)5 citations · $2,000
1910.1063 citations · $2,000
1910.1200Hazard Communication3 citations · $2,000

Chemical exposure sampling

Samples
23
Substances
17
Inspections
1

Industry comparison

Violations per inspection
This employer28.0
Industry average3.3
Penalties per inspection
This employer$18,000
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,936 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: sheet metal work manufacturing reported 3.3 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.4%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Dayton, OH