Skip to content
SafetyRecord logoSafetyRecord
FLEX TECHNOLOGIES, INC.
$15,286
penalties
64
viol.
8
insp.

FLEX TECHNOLOGIES, INC.

5498 GUNDY DRIVE, MIDVALE, OH 44653NAICS 326122 Plastics Pipe and Pipe Fitting Manufacturing

Inspections
8
Oct 1988 to Dec 2012 · 6 safety, 2 health
Violations
64
across 8 inspections
Penalties on record
$15,286
latest amounts in DOL records
By classification
Serious 32Willful 0Repeat 1Other 31

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 27, 2012Complaint (B) · Partial scope, Safety#338021884$4,2854 viol.

Inspection #338021884

Dates

Opened
Dec 27, 2012
Closing Conference Date
Dec 27, 2012
Contested
Feb 13, 2013
Final Order
Sep 12, 2013
Closed
Dec 17, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
21
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$12,240
Penalties on Record
$4,285
Site Address
5479 Gundy Drive, Midvale, OH 44653
Industry
326121 Unlaminated Plastics Profile Shape Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious11$3,825$1,339Oct 14, 2013Feb 13, 2013Sep 12, 2013
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 I
Serious15$3,825$1,339Oct 14, 2013Feb 13, 2013Sep 12, 2013
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 II
Serious14$3,825$1,339Oct 14, 2013Feb 13, 2013Sep 12, 2013
020011904.29
Forms
OSHA citation code: 19040029 B01
Other321$765$268Feb 13, 2013Sep 12, 2013
Mar 1, 2012Complaint (B) · Partial scope, Safety#332429422$1,5003 viol.

Inspection #332429422

Dates

Opened
Mar 1, 2012
Closing Conference Date
Mar 1, 2012
Contested
Mar 28, 2012
Final Order
Jan 10, 2013
Closed
Mar 18, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
1 repeat, 2 other-than-serious
Initial Penalties
$30,000
Penalties on Record
$1,500
Site Address
5498 Gundy Drive, Midvale, OH 44653
Industry
326121 Unlaminated Plastics Profile Shape Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Other120$5,000$500Feb 10, 2013Mar 28, 2012Jan 10, 2013
020011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Repeat120$25,000$1,000Feb 11, 2013Mar 28, 2012Jan 10, 2013
030011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Other120$0$0Feb 11, 2013Mar 28, 2012Jan 10, 2013
Feb 3, 2010Planned (H) · Complete scope, Safety#313154171$3251 viol.

Inspection #313154171

Dates

Opened
Feb 3, 2010
Closing Conference Date
Feb 17, 2010
Contested
Mar 23, 2010
Final Order
Jul 12, 2010
Closed
Aug 19, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$1,300
Penalties on Record
$325
Site Address
5479 Gundy Drive, Midvale, OH 44653
Industry
326121 Unlaminated Plastics Profile Shape Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other11$1,300$325Mar 12, 2010Mar 23, 2010Jul 12, 2010
Jun 26, 2008Planned (H) · Partial scope, Safety#311835326$3,92316 viol.

Inspection #311835326

Dates

Opened
Jun 26, 2008
Closing Conference Date
Jun 26, 2008
Closed
Sep 9, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
19

Violations and Penalties

Total Violations
16
Violation Types
10 serious, 6 other-than-serious
Initial Penalties
$11,200
Penalties on Record
$3,923
Site Address
5479 Gundy Drive, Midvale, OH 44653
Industry
326121 Unlaminated Plastics Profile Shape Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 F
Other12$1,400$858Aug 5, 2008--
01001B1910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 H
Other12$0$0Aug 5, 2008--
01002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious115$1,750$613Sep 5, 2008--
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious115$0$0Sep 5, 2008--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious814$1,750$613Sep 5, 2008--
01004A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious12$1,750$613Aug 5, 2008--

Showing the 6 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Feb 13, 2003Planned (H) · Partial scope, Safety#305435414$4732 viol.

Inspection #305435414

Dates

Opened
Feb 13, 2003
Closing Conference Date
Feb 13, 2003
Closed
Mar 10, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$675
Penalties on Record
$473
Site Address
5479 Gundy Drive, Midvale, OH 44653
Industry
326122 Plastics Pipe and Pipe Fitting Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious11$675$473Mar 11, 2003--
020011910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other11$0$0Mar 11, 2003--
Sep 13, 1999Complaint (B) · Partial scope, Health#122057680$03 viol.

Inspection #122057680

Dates

Opened
Sep 13, 1999
Closing Conference Date
Sep 21, 1999
Closed
Oct 21, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
61
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
5479 Gundy Drive, Midvale, OH 44653
Industry
326122 Plastics Pipe and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Formaldehyde60ppm

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
02001A1904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other461$0$0Oct 18, 1999--
02001B1904.5
Determination of Work-Relatedness
OSHA citation code: 19040005 C
Other261$0$0Oct 18, 1999--
020021910.1048
Formaldehyde
OSHA citation code: 19101048 O05 I
Other120$0$0Nov 2, 1999--
Nov 3, 1988Planned (H) · Complete scope, Safety#103529970$3,50030 viol.

Inspection #103529970

Dates

Opened
Nov 3, 1988
Closing Conference Date
Nov 14, 1988
Contested
Jan 30, 1989
Closed
Nov 30, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
66

Violations and Penalties

Total Violations
30
Violation Types
14 serious, 16 other-than-serious
Initial Penalties
$8,900
Penalties on Record
$3,500
Site Address
5479 Gundy Drive, Midvale, OH 44653
Industry
326122 Plastics Pipe and Pipe Fitting Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Enforcement Outcome

Citation contest activity appears on Jan 30, 1989. Final orders are recorded through Sep 25, 1989. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (6 of 30 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A02
Serious22$270$135Jan 6, 1989Jan 30, 1989Sep 25, 1989
010021910.23
Ladders
OSHA citation code: 19100023 A09
Serious12$270$135Jan 6, 1989Jan 30, 1989Sep 25, 1989
010031910.23
Ladders
OSHA citation code: 19100023 C01
Serious84$450$225Jan 6, 1989Jan 30, 1989Sep 25, 1989
010041910.23
Ladders
OSHA citation code: 19100023 C03
Serious54$450$225Feb 3, 1989Jan 30, 1989Sep 25, 1989
010051910.23
Ladders
OSHA citation code: 19100023 D01 III
Serious110$540$230Jan 18, 1989Jan 30, 1989Sep 25, 1989
010061910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 B
Serious54$450$225Feb 3, 1989Jan 30, 1989Sep 25, 1989

Showing the 6 violations listed first by citation identifier. This inspection has 30 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 13, 1988Referral (C) · Partial scope, Health#103535167$1,2805 viol.

Inspection #103535167

Dates

Opened
Oct 13, 1988
Closing Conference Date
Oct 13, 1988
Closed
Sep 21, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
35
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
4 serious, 1 other-than-serious
Initial Penalties
$10,280
Penalties on Record
$1,280
Site Address
5479 Gundy Drive, Midvale, OH 44653
Industry
326122 Plastics Pipe and Pipe Fitting Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.20
Access to Employee Exposure and Medical Records
OSHA citation code: 19100020 E05 I
Serious12$5,000$500Jan 4, 1989--
010021910.20
Access to Employee Exposure and Medical Records
OSHA citation code: 19100020 E02 IIIA
Serious12$5,000$500Jan 4, 1989--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Serious12$140$140Jan 4, 1989--
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Serious12$140$140Jan 4, 1989--
030011910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Other12$0$0Jan 4, 1989--
Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment9 citations · $3,989
1910.219Mechanical Power-Transmission Apparatus6 citations · $1,143
1910.303Electrical - General Requirements6 citations · $693

Chemical exposure sampling

Samples
6
Substances
1
Inspections
1

Industry comparison

Violations per inspection
This employer8.0
Industry average2.8
Penalties per inspection
This employer$1,911
Industry average$3,072

Plastics and Rubber Products Manufacturing, 13,333 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in MIDVALE, OH

All employers in MIDVALE →