Skip to content
SafetyRecord logoSafetyRecord
WESTERN SLOPE INDUSTRIES
$4,450
penalties
21
viol.
3
insp.

WESTERN SLOPE INDUSTRIES

769 VALLEY COURT, GRAND JUNCTION, CO 81504

Inspections
3
Mar 1986 to Aug 2003 · 2 safety, 1 health
Violations
21
across 3 inspections
Penalties on record
$4,450
latest amounts in DOL records
By classification
Serious 10Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 11, 2003Complaint (B) · Partial scope, Safety#306371857$3,4508 viol.

Inspection #306371857

Dates

Opened
Aug 11, 2003
Closing Conference Date
Aug 11, 2003
Closed
Nov 3, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60
Related Activity
1 complaint

Violations and Penalties

Total Violations
8
Violation Types
7 serious, 1 other-than-serious
Initial Penalties
$5,825
Penalties on Record
$3,450
Site Address
2524 Foresight Circle, Grand Junction, CO 81505
Industry
333291

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Serious160$700$400Sep 18, 2003--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Serious260$700$400Sep 22, 2003--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious160$1,225$750Sep 22, 2003--
010041910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious660$700$400Sep 22, 2003--
01005A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IIIA
Serious160$2,500$1,500Sep 22, 2003--
01005B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious260$0$0Sep 22, 2003--
01005C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J01 I
Serious260$0$0Sep 22, 2003--
020011910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other660$0$0Sep 22, 2003--
May 15, 1996Complaint (B) · Partial scope, Safety#301171021$1,0003 viol.

Inspection #301171021

Dates

Opened
May 15, 1996
Closing Conference Date
May 15, 1996
Closed
Jun 17, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
80
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$1,750
Penalties on Record
$1,000
Site Address
2524 Foresight Cir., Grand Junction, CO 81505
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.26
Dockboards
OSHA citation code: 19100026 C02 VII
Serious13$875$500May 22, 1996--
01002A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 A06
Serious13$875$500Jun 6, 1996--
01002B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Serious13$0$0Jun 6, 1996--
Mar 26, 1986Complaint (B) · Partial scope, Health#100022896$010 viol.

Inspection #100022896

Dates

Opened
Mar 26, 1986
Closing Conference Date
Mar 26, 1986
Closed
Sep 11, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
10 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
769 Valley Court, Grand Junction, CO 81504
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)90mg/m³
Beryllium and Beryllium Compounds (as Be)90mg/m³
Cadmium Fume (as Cd)90mg/m³
Chromium, Metal and Insoluble Salts90 - 0.0191mg/m³
Cobalt, Metal, Dust and Fume (as Co)90 - 0.0157mg/m³
Copper Fume (as Cu)90 - 0.0221mg/m³
Iron Oxide Fume90 - 2.9254mg/m³
Lead, Inorganic (as Pb)90mg/m³
Manganese Fume (as Mn)90 - 0.1112mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)90mg/m³
Nickel, Metal and Insoluble compounds (as Ni)90 - 0.0332mg/m³
Particulates not otherwise regulated (Respirable Fraction)90mg/m³
Vanadium fume (as V2O5)90mg/m³
Zinc Oxide Fume90 - 0.858mg/m³

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other123$0$0Aug 1, 1986--
010021904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other123$0$0Aug 1, 1986--
01003A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other12$0$0Sep 19, 1986--
01003B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Other110$0$0Aug 1, 1986--
01003C1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Other12$0$0Nov 7, 1986--
01003D1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Other12$0$0Nov 7, 1986--
01003E1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 L01
Other110$0$0Aug 1, 1986--
01004A1910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Other11$0$0Sep 5, 1986--
01004B1910.134
Respiratory Protection
OSHA citation code: 19100134 B02
Other11$0$0Aug 8, 1986--
01004C1910.134
Respiratory Protection
OSHA citation code: 19100134 B03
Other11$0$0Sep 5, 1986--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.95Occupational Noise Exposure5 citations · $0
1910.134Respiratory Protection3 citations · $0
1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $1,500

Chemical exposure sampling

Samples
126
Substances
14
Inspections
1

Other inspected employers in GRAND JUNCTION, CO

All employers in GRAND JUNCTION →